主页 文献库文献详情
PMID: 27334134 已发表 · ppublish 英语

Comparison of the accuracy between robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis.

Liu Hao, Chen Weikai, Wang Zongyi, Lin Jun, Meng Bin, Yang Huilin

摘要

To perform a systematic review and meta-analysis to investigate the different of accuracy between robot-assisted and conventional freehand pedicle screw placement.,The electronic databases of PubMed, Ovid MEDLINE, EMBASE, and Web of Science were searched for the literatures published up to January, 2016. Statistical analysis was performed using the Review Manager 5.3. The dichotomous data for the pedicle violation rate were summarized using relative risk (RR) and 95 % confidence intervals (CIs). The level of significance was set at [Formula: see text].,A total of 257 patients and 1105 screws were included in the five studies for this meta-analysis. The results revealed that there was no difference in the accuracy between robot-assisted and conventional freehand pedicle screw placement at the 0 mm grading criteria (RR 1.08, 95 % CI 0.86, 1.35, [Formula: see text], [Formula: see text]) and at 2 mm grading criteria (RR 1.02, 95 % CI 0.68, 1.51, [Formula: see text], [Formula: see text]). Among percutaneous robot-assisted technique, open robot-assisted technique and conventional freehand technique, there was also no significant difference at 0mm grading criteria (RO(P) vs FH : RR 1.10, 95 % CI 0.87, 1.40, [Formula: see text], [Formula: see text]; RO(O) versus FH : RR 0.87, 95 % CI 0.55, 1.38, [Formula: see text], [Formula: see text]; RO(P) vs RO(O): RR 1.20, 95 % CI 0.65, 2.24, [Formula: see text]) and at 2 mm grading criteria(RO(P) vs FH : RR 1.07, 95 % CI 0.43, 2.67, [Formula: see text], [Formula: see text]; RO(O) vs FH : RR 0.71, 95 % CI 0.36, 1.39, [Formula: see text], [Formula: see text]; RO(P) vs RO(O) : RR 0.84, 95 % CI 0.36, 1.94, [Formula: see text]).,Further high-quality studies are required to unequivocally recommend one surgical technique over the other. With the more application of robot-assisted navigation system, accuracy and clinical benefit of the technique will be gradually improved.

关键词
Accuracy Navigation Pedicle screw Robot assisted Spinal surgery
文献信息
期刊
International journal of computer assisted radiology and surgery
期刊简称
Int J Comput Assist Radiol Surg
发表日期
0000-00-00
收录日期
2016-06-23
更新日期
2016-11-16
语言
英语
国家/地区
Germany
NLM ID
101499225
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: [email protected]