Home LiteratureArticle Details
PMID: 2754004 Published · ppublish English Journal Article

Staphylococcus aureus strains which are not identified by rapid agglutination methods are of capsular serotype 5.

Journal of clinical microbiology ·Vol. 27 ·No. 6 ·1989-06-00 ·Pages 1372-4

Fournier JM, Boutonnier A, Bouvet A

Abstract

A total of 183 recent Staphylococcus aureus clinical isolates were tested with three commercially available rapid agglutination methods. The capsular polysaccharide type and resistance to oxacillin of these isolates were also determined. Seven isolates were not identified correctly by agglutination methods. All isolates not identified by the rapid methods were of capsular serotype 5, and of these isolates, six were resistant to oxacillin. The results suggest that these agglutination kits can be improved by the use of antibodies reactive with S. aureus capsular polysaccharide.

MeSH Terms
Agglutination Tests Bacterial Capsules Hemagglutination Tests Latex Fixation Tests Microbial Sensitivity Tests Oxacillin/pharmacology Penicillin Resistance Polysaccharides, Bacterial/analysis,immunology Reagent Kits, Diagnostic Serotyping Staphylococcus aureus/classification,drug effects,immunology,isolation & purification
Chemicals
Polysaccharides, Bacterial Reagent Kits, Diagnostic capsular polysaccharide, type 5, Staphylococcus aureus Oxacillin
Authors & Affiliations
3 authors, click to expand affiliations / ORCID
Fournier J M
Institut Pasteur, Paris, France.
Boutonnier A
Bouvet A
References (21)
21 references, click to expand
  1. Evaluation of the latex slide agglutination test for identification of Staphylococcus aureus.
    J Clin Microbiol. 1982 Feb;15(2):275-7 PMID: 7068822
  2. Rapid and reliable identification of Staphylococcus aureus by a latex agglutination test.
    J Clin Microbiol. 1980 Nov;12(5):641-3 PMID: 7024295
  3. Evaluation of a commercial latex agglutination test for identification of Staphylococcus aureus.
    J Clin Microbiol. 1982 Mar;15(3):416-8 PMID: 7076815
  4. Comparison of two commercially available test methods with conventional coagulase tests for identification of Staphylococcus aureus.
    J Clin Microbiol. 1984 Feb;19(2):191-3 PMID: 6365958
  5. Predominance of two newly described capsular polysaccharide types among clinical isolates of Staphylococcus aureus.
    Diagn Microbiol Infect Dis. 1984 Apr;2(2):85-91 PMID: 6232086
  6. Comparison of rapid identification assays for Staphylococcus aureus.
    J Clin Microbiol. 1984 May;19(5):703-4 PMID: 6376540
  7. Evaluation of three commercial agglutination tests for the identification of Staphylococcus aureus.
    J Clin Microbiol. 1984 Oct;20(4):614-7 PMID: 6490847
  8. Evaluation of various rapid agglutination methods for the identification of Staphylococcus aureus.
    J Clin Microbiol. 1985 May;21(5):726-9 PMID: 3998102
  9. Method for the serological typing of the capsular polysaccharides of Staphylococcus aureus.
    J Clin Microbiol. 1985 Sep;22(3):445-7 PMID: 3930565
  10. Encapsulation and capsular types in isolates of Staphylococcus aureus from different sources and relationship to phage types.
    J Clin Microbiol. 1985 Nov;22(5):828-34 PMID: 2932464
  11. Comparison of a yellow latex reagent with other agglutination methods for the identification of Staphylococcus aureus.
    J Clin Microbiol. 1986 Mar;23(3):640-2 PMID: 3958152
  12. Evaluation of rapid coagulase methods for the identification of Staphylococcus aureus.
    J Clin Microbiol. 1986 May;23(5):916-9 PMID: 3635533
  13. Comparative evaluation of identification systems for testing methicillin-resistant strains of Staphylococcus aureus.
    J Clin Microbiol. 1986 Aug;24(2):173-6 PMID: 3638308
  14. Failure of rapid agglutination methods to detect oxacillin-resistant Staphylococcus aureus.
    J Clin Microbiol. 1986 Sep;24(3):490-2 PMID: 3489732
  15. Reliability of latex agglutination tests for identification of Staphylococcus aureus resistant to oxacillin.
    J Clin Microbiol. 1986 Dec;24(6):1104-6 PMID: 3640773
  16. Serotyping and electron microscopy studies of Staphylococcus aureus clinical isolates with monoclonal antibodies to capsular polysaccharide types 5 and 8.
    J Clin Microbiol. 1987 Mar;25(3):526-30 PMID: 2437148
  17. Predominance of capsular polysaccharide type 5 among oxacillin-resistant Staphylococcus aureus.
    J Clin Microbiol. 1987 Oct;25(10):1932-3 PMID: 3667914
  18. Prevalence of capsular polysaccharide types 5 and 8 among Staphylococcus aureus isolates from cow, goat, and ewe milk.
    J Clin Microbiol. 1988 Jan;26(1):38-40 PMID: 3343313
  19. Efficacies of rapid agglutination tests for identification of methicillin-resistant staphylococcal strains as Staphylococcus aureus.
    J Clin Microbiol. 1988 Sep;26(9):1907-9 PMID: 3183033
  20. Sensitized sheep red cells as a reactant for Staphylococcus aureus protein A. Methodology and epidemiology with special reference to weakly reacting methicillin-resistant strains.
    Acta Pathol Microbiol Scand B Microbiol Immunol. 1973 Feb;81(1):150-6 PMID: 4517042
  21. Study of the staphylococcal affinity to fibrinogen by passive hemagglutination: a tool for the Staphylococcus aureus identification.
    Zentralbl Bakteriol Mikrobiol Hyg A. 1981 Dec;251(2):171-6 PMID: 7200300
Article Info
Journal
Journal of clinical microbiology
Abbr.
J Clin Microbiol
ISSN
0095-1137
Published
1989-06-00
Pages
1372-4
Language
English
Region
United States
NLM ID
7505564
PMCID
PMC267559
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]