Home LiteratureArticle Details
PMID: 28133372 Published · ppublish English Journal Article

Numerical investigations of the unsteady blood flow in the end-to-side arteriovenous fistula for hemodialysis.

Acta of bioengineering and biomechanics ·Vol. 18 ·No. 4 ·2016-00-00 ·页码 3-13

Jodko D, Obidowski D, Reorowicz P, Jóźwik K

Abstract

The aim of this study was to investigate the blood flow in the end-to-side arteriovenous (a-v) fistula, taking into account its pulsating nature and the patient-specific geometry of blood vessels. Computational Fluid Dynamics (CFD) methods were used for this analysis. DICOM images of the fistula, obtained from the angio-computed tomography, were a source of the data applied to develop a 3D geometrical model of the fistula. The model was meshed, then the ANSYS CFX v. 15.0 code was used to perform simulations of the flow in the vessels under analysis. Mesh independence tests were conducted. The non-Newtonian rheological model of blood and the Shear Stress Transport model of turbulence were employed. Blood vessel walls were assumed to be rigid. Flow patterns, velocity fields, the volume flow rate, the wall shear stress (WSS) propagation on particular blood vessel walls were shown versus time. The maximal value of the blood velocity was identified in the anastomosis - the place where the artery is connected to the vein. The flow rate was calculated for all veins receiving blood. The blood flow in the geometrically complicated a-v fistula was simulated. The values and oscillations of the WSS are the largest in the anastomosis, much lower in the artery and the lowest in the cephalic vein. A strong influence of the mesh on the results concerning the maximal and area-averaged WSS was shown. The relation between simulations of the pulsating and stationary flow under time-averaged flow conditions was presented.

MeSH 主题词
Arteriovenous Shunt, Surgical Blood Flow Velocity/physiology Blood Pressure/physiology Computer Simulation Humans Models, Cardiovascular Radial Artery/physiology,surgery Shear Strength Vascular Resistance/physiology Veins/physiology,surgery
作者与单位
共 4 位作者,点击展开单位 / ORCID
Jodko Daniel
Lodz University of Technology, Institute of Turbomachinery, Lodz, Poland.
Obidowski Damian
Lodz University of Technology, Institute of Turbomachinery, Lodz, Poland.
Reorowicz Piotr
Lodz University of Technology, Institute of Turbomachinery, Lodz, Poland.
Jóźwik Krzysztof
Lodz University of Technology, Institute of Turbomachinery, Lodz, Poland.
Article Info
Journal
Acta of bioengineering and biomechanics
Abbr.
Acta Bioeng Biomech
ISSN
1509-409X
Published
2016-00-00
页码
3-13
Language
English
Country/Region
Poland
NLM ID
101194794
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]