Comparison of Accuracy of One-Use Methods for Calculating Fractional Flow Reserve by Intravascular Optical Coherence Tomography to That Determined by the Pressure-Wire Method.

The American journal of cardiology ·Vol. 120 ·No. 11 ·2017-12-01 ·页码 1920-1925

Jang SJ, Ahn JM, Kim B, Gu JM, Sung HJ, Park SJ, Oh WY

Abstract

Although the identification of the hemodynamic significance of coronary lesions becomes important for revascularization strategy, the potential role of 3-dimensional high-resolution intracoronary optical coherence tomography (OCT) for predicting functional significance of coronary lesions remains unclear. We assessed the diagnostic performance of 2 computational approaches for deriving fractional flow reserve (FFR) from intravascular OCT images. We developed 2 methods to derive FFR-OCT by AFD (FFR-OCTAFD) and FFR-OCT by CFD (FFR-OCTCFD). Among 217 eligible patients between 2011 and 2014, 104 were included for data analysis (9 for derivation, 95 for validation). Luminal geometries from 3-dimensional OCT were used for both FFR-OCTAFD and FFR-OCTCFD calculations. The analytical fluid dynamics method calculated FFR from the blood flow resistance estimated using Poiseuille's law. For computational fluid dynamics, we numerically solved the Navier-Stokes equation in a steady-state flow with the distal porous media model for the capillary vessels. We examined the diagnostic performance of FFR-OCTAFD and FFR-OCTCFD compared with the pressure-wire measured FFR. The accuracy, sensitivity, specificity, PPV, and NPV were 86%, 65%, 94%, 81%, and 88% for FFR-OCTAFD and 86%, 73%, 91%, 76%, and 90% for FFR-OCTCFD. The area under the curve of the receiver-operating characteristic curve was 0.88 for FFR-OCTAFD and 0.86 for FFR-OCTCFD. FFR-OCTAFD and FFR-OCTCFD showed a strong linear correlation with the measured FFR (r = 0.631; p <0.001, r = 0.655; p <0.001, respectively). FFR derived from high-resolution volumetric OCT images showed high diagnostic performance for the detection of coronary ischemia. In conclusion, OCT-derived FFR may be useful for guiding the management of coronary artery disease.

MeSH 主题词
Capillaries/pathology,physiopathology Cardiac Catheterization/methods Coronary Artery Disease/diagnosis,physiopathology Coronary Vessels/diagnostic imaging,pathology,physiopathology Female Follow-Up Studies Fractional Flow Reserve, Myocardial Humans Imaging, Three-Dimensional/methods Male Microcirculation Middle Aged Pressure ROC Curve Retrospective Studies Severity of Illness Index Tomography, Optical Coherence/methods
作者与单位
共 7 位作者,点击展开单位 / ORCID
Jang Sun-Joo
Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea; KI for Health Science and Technology, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea; Heart Institute, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea; Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts.
Ahn Jung-Min
Heart Institute, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.
Kim Boyoung
Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea.
Gu Ji-Min
Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea.
Sung Hyung Jin
Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea.
Park Seung-Jung
Heart Institute, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea. Electronic address: [email protected].
Oh Wang-Yuhl
Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea; KI for Health Science and Technology, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea. Electronic address: [email protected].
Article Info
Journal
The American journal of cardiology
Abbr.
Am J Cardiol
ISSN
1879-1913
Published
2017-12-01
电子出版
2017-00-01
页码
1920-1925
Language
English
Country/Region
United States
NLM ID
0207277
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]