Home LiteratureArticle Details
PMID: 29720173 Published · epublish English Journal Article

Clinical validation and assessment of aortic hemodynamics using computational fluid dynamics simulations from computed tomography angiography.

Biomedical engineering online ·Vol. 17 ·No. 1 ·2018-05-02 ·页码 53

Zhu Y, Chen R, Juan YH, Li H, Wang J, Yu Z, Liu H

Abstract

Hemodynamic information including peak systolic pressure (PSP) and peak systolic velocity (PSV) carry an important role in evaluation and diagnosis of congenital heart disease (CHD). Since MDCTA cannot evaluate hemodynamic information directly, the aim of this study is to provide a noninvasive method based on a computational fluid dynamics (CFD) model, derived from multi-detector computed tomography angiography (MDCTA) raw data, to analyze the aortic hemodynamics in infants with CHD, and validate these results against echocardiography and cardiac catheter measurements. This study included 25 patients (17 males, and 8 females; a median age of 2 years, range: 4 months-4 years) with CHD. All patients underwent both transthoracic echocardiography (TTE) and MDCTA within 2 weeks prior to cardiac catheterization. CFD models were created from MDCTA raw data. Boundary conditions were confirmed by lumped parameter model and transthoracic echocardiography (TTE). Peak systolic velocity derived from CFD models (PSVCFD) was compared to TTE measurements (PSVTTE), while the peak systolic pressure derived from CFD (PSPCFD) was compared to catheterization (PSPCC). Regions with low and high peak systolic wall shear stress (PSWSS) were also evaluated. PSVCFD and PSPCFD showed good agreements between PSVTTE (r = 0.968, p < 0.001; mean bias = - 7.68 cm/s) and PSPCC (r = 0.918, p < 0.001; mean bias = 1.405 mmHg). Regions with low and high PSWSS) can also be visualized. Skewing of velocity or helical blood flow was also observed at aortic arch in patients. Our result demonstrated that CFD scheme based on MDCTA raw data is an accurate and convenient method in obtaining the velocity and pressure from aorta and displaying the distribution of PSWSS and flow pattern of aorta. The preliminary results from our study demonstrate the capability in combining clinical imaging data and novel CFD tools in infants with CHD and provide a noninvasive approach for diagnose of CHD such as coarctation of aorta in future.

Keywords
Aortic hemodynamics Computational fluid dynamics Congenital heart disease Multi-detector computed tomography angiography
MeSH 主题词
Aorta/diagnostic imaging,physiology Child, Preschool Computed Tomography Angiography Computer Simulation Female Hemodynamics Humans Hydrodynamics Infant Male Reproducibility of Results Systole/physiology
作者与单位
共 7 位作者,点击展开单位 / ORCID
Zhu Yulei
Department of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, No. 106, Zhong Shan Er Lu, Guangzhou, 510080, Guangdong, China. | School of Medicine, South China University of Technology, Guangzhou, 510006, Guangdong, China.
Chen Rui
Department of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, No. 106, Zhong Shan Er Lu, Guangzhou, 510080, Guangdong, China. | School of Medicine, South China University of Technology, Guangzhou, 510006, Guangdong, China.
Juan Yu-Hsiang
Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou Chang Gung University, Taoyuan, Taiwan.
Li He
Department of Cardiac Surgery, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong General Hospital, Guangdong Academy of Medical Sciences, No. 106, Zhong Shan Er Lu, Guangzhou, 510080, Guangdong, China.
Wang Jingjing
Department of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, No. 106, Zhong Shan Er Lu, Guangzhou, 510080, Guangdong, China. | School of Medicine, South China University of Technology, Guangzhou, 510006, Guangdong, China.
Yu Zhuliang
School of Medicine, South China University of Technology, Guangzhou, 510006, Guangdong, China. [email protected]. | College of Automation Science and Technology, South China University of Technology, 381 Wushan Road, Guangzhou, 510080, Guangdong, China. [email protected].
Liu Hui
Department of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, No. 106, Zhong Shan Er Lu, Guangzhou, 510080, Guangdong, China. [email protected]. | School of Medicine, South China University of Technology, Guangzhou, 510006, Guangdong, China. [email protected].
Article Info
Journal
Biomedical engineering online
Abbr.
Biomed Eng Online
ISSN
1475-925X
Published
2018-05-02
电子出版
2018-00-02
页码
53
Language
English
Country/Region
England
NLM ID
101147518
基金资助
National Natural Science Foundation of China · 81771799
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]