Home LiteratureArticle Details
PMID: 30211982 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't

The FDA nozzle benchmark: "In theory there is no difference between theory and practice, but in practice there is".

International journal for numerical methods in biomedical engineering ·Vol. 35 ·No. 1 ·2019-00-00 ·Pages e3150

Bergersen AW, Mortensen M, Valen-Sendstad K

Abstract

The utility of flow simulations relies on the robustness of computational fluid dynamics (CFD) solvers and reproducibility of results. The aim of this study was to validate the Oasis CFD solver against in vitro experimental measurements of jet breakdown location from the FDA nozzle benchmark at Reynolds number 3500, which is in the particularly challenging transitional regime. Simulations were performed on meshes consisting of 5, 10, 17, and 28 million (M) tetrahedra, with Δt  =  10-5 seconds. The 5M and 10M simulation jets broke down in reasonable agreement with the experiments. However, the 17M and 28M simulation jets broke down further downstream. But which of our simulations are "correct"? From a theoretical point of view, they are all wrong because the jet should not break down in the absence of disturbances. The geometry is axisymmetric with no geometrical features that can generate angular velocities. A stable flow was supported by linear stability analysis. From a physical point of view, a finite amount of "noise" will always be present in experiments, which lowers transition point. To replicate noise numerically, we prescribed minor random angular velocities (approximately 0.31%), much smaller than the reported flow asymmetry (approximately 3%) and model accuracy (approximately 1%), at the inlet of the 17M simulation, which shifted the jet breakdown location closer to the measurements. Hence, the high-resolution simulations and "noise" experiment can potentially explain discrepancies in transition between sometimes "sterile" CFD and inherently noisy "ground truth" experiments. Thus, we have shown that numerical simulations can agree with experiments, but for the wrong reasons.

Keywords
FDA nozzle benchmark computational fluid dynamics noise transitional flow turbulence validation
MeSH Terms
Benchmarking Computer Simulation Hydrodynamics United States United States Food and Drug Administration
Authors & Affiliations
3 authors, click to expand affiliations / ORCID
Bergersen Aslak W
Department of Computational Physiology, Simula Research Laboratory AS, Fornebu, Norway.
Mortensen Mikael ORCID
Department of Mathematics, University of Oslo Mathematics and Natural Sciences, Oslo, Norway.
Valen-Sendstad Kristian ORCID
Department of Computational Physiology, Simula Research Laboratory AS, Fornebu, Norway.
Article Info
Journal
International journal for numerical methods in biomedical engineering
Abbr.
Int J Numer Method Biomed Eng
ISSN
2040-7947
Published
2019-00-00
Epub
2018-00-22
Pages
e3150
Language
English
Region
England
NLM ID
101530293
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]