On the Accuracy of Hemolysis Models in Couette-Type Blood Shearing Devices.

Artificial organs ·Vol. 42 ·No. 10 ·2018-10-00 ·Pages E290-E303

Wu P, Boehning F, Groß-Hardt S, Hsu PL

Abstract

Hemolysis is one of the most challenging issues faced by blood contacting devices. Empirical hemolysis models often relate hemolysis to shear stress and exposure time. These models were generally derived from the experimental results of Couette-type blood shearing devices, with assumption of uniform exposure time and shear stress. This assumption is not strictly valid since neither exposure time nor shear stress is uniform. Hence, this study evaluated the influence of the nonuniform exposure time and rotor eccentricity or run-out on the accuracy of power-law hemolysis models, using both theoretical and CFD analysis. This work first provided a systematic analysis of the flow regime in a typical Couette shearing device, and showed the axial flow component can be regarded as fully developed laminar plane Poiseuille flow. It was found that the influence of nonuniform exposure time is within 4% for several widely used power-law models, which were validated by steady CFD simulations. A theoretical relationship was then built between the rotor run-out and hemolysis. We noticed that the influence of rotor run-out on hemolysis is within 5% for a moderate rotor run-out ratio of 0.2. Next, transient CFD simulations were performed to investigate the influence of rotor run-out on hemolysis with run-out ratios of 0.1 and 0.2. The results showed negligible effects for a moderate run-out ratio of 0.1. However, a run-out ratio of 0.2 led to a significant increase of hemolysis, resulting from back flows induced by the run-out of the rotor. These findings will be of great importance for the improvement of the hemolysis estimation and blood compatibility design.

Keywords
Computational fluid dynamics Couette shearing device Exposure time Hemolysis model Rotor eccentricity
MeSH 主题词
Blood Flow Velocity Computer Simulation Equipment Design Heart-Assist Devices/adverse effects Hemolysis Humans Hydrodynamics Models, Cardiovascular Stress, Mechanical Time Factors
Authors & Affiliations
4 authors, click to expand affiliations / ORCID
Wu Peng ORCID
Artificial Organ Technology Lab, Bio-manufacturing Research Centre, School of Mechanical and Electric Engineering, Soochow University, Suzhou, Jiangsu, China.
Boehning Fiete
enmodes GmbH, Aachen, Germany.
Groß-Hardt Sascha
Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany.
Hsu Po-Lin
Artificial Organ Technology Lab, Bio-manufacturing Research Centre, School of Mechanical and Electric Engineering, Soochow University, Suzhou, Jiangsu, China.
Article Info
Journal
Artificial organs
Abbr.
Artif Organs
ISSN
1525-1594
Published
2018-10-00
Pages
E290-E303
Language
English
Country/Region
United States
NLM ID
7802778
基金资助
National Natural Science Foundation of China · 51406127
Natural Science Foundation of China · 51406127
Natural Science Foundation of Jiangsu Province · BK20140344
China Scholarship Council
German Academic Exchange Service
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]