Home LiteratureArticle Details
PMID: 30688694 Published · ppublish English Journal Article

Dual-Propeller Cavopulmonary Pump for Assisting Patients with Hypoplastic Right Ventricle.

ASAIO journal (American Society for Artificial Internal Organs : 1992) ·Vol. 65 ·No. 8 ·2019-00-00 ·页码 888-897

Jagani JN, Untaroiu A, Kalaria AD

Abstract

Various congenital heart defects (CHDs) are characterized by the existence of a single functional ventricle, which perfuses both the systemic and pulmonary circulation. A three-stage palliation procedure, including the final Fontan completion, is often adopted by surgeons to treat patients with such CHDs. The completion Fontan involves the creation of a total cavopulmonary connection (TCPC), commonly accomplished with an extracardiac conduit. This TCPC results in nonphysiologic flow conditions that can lead to systemic venous hypertension, reduced cardiac output, and ultimately the need for heart transplantation. A modest pressure rise of 5-6 mm Hg could correct the abnormal flow dynamics in these patients. To achieve this, we propose a novel conceptual design of a dual-propeller pump inside a flared TCPC. The TCPC dual-propeller conjunction was examined for hydraulic performance, blood flow pattern, and potential for hemolysis inside the TCPC using computational fluid dynamics (CFD). The effect of axial distance between the two propellers on the blood flow interference and energy loss was studied to determine the optimal separation distance. Both the inferior vena cava (IVC) and superior vena cava (SVC) propellers provided a pressure rise of 1-20 mm Hg at flow rates ranging from 0.4 to 7 lpm while rotating at speeds of 6,000-12,000 rpm. Larger separation distance provided favorable performance in terms of flow interference, energy loss, and blood damage potential. The ability of a dual-propeller micropump to provide the required pressure rise would help to augment the cavopulmonary flow and mimic flows seen in normal biventricular circulation.

MeSH 主题词
Equipment Design Fontan Procedure/instrumentation,methods Heart Defects, Congenital/surgery Heart Ventricles/abnormalities,surgery Heart-Assist Devices Humans Hydrodynamics Models, Cardiovascular
作者与单位
共 3 位作者,点击展开单位 / ORCID
Jagani Jakin N
From the Department of Mechanical Engineering, Virginia Polytechnic Institute and State University, Blacksburg, Virginia.
Untaroiu Alexandrina
Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia.
Kalaria Amit D
Department of Radiology, MedStar Medical Group Radiology, Baltimore, Maryland.
Article Info
Journal
ASAIO journal (American Society for Artificial Internal Organs : 1992)
Abbr.
ASAIO J
ISSN
1538-943X
Published
2019-00-00
页码
888-897
Language
English
Country/Region
United States
NLM ID
9204109
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]