Home LiteratureArticle Details
PMID: 32218903 Published · ppublish English Journal Article

Large-eddy simulation of the containment failure in isolation rooms with a sliding door-An experimental and modelling study.

Building simulation ·Vol. 11 ·No. 3 ·2018-00-00 ·页码 585-596

Saarinen P, Kalliomäki P, Koskela H, Tang JW

Abstract

In hospital isolation rooms, door operation can lead to containment failures and airborne pathogen dispersal into the surrounding spaces. Sliding doors can reduce the containment failure arising from the door motion induced airflows, as compared to the hinged doors that are typically used in healthcare facilities. Such airflow leakage can be measured quantitatively using tracer gas techniques, but detailed observation of the turbulent flow features is very difficult. However, a comprehensive understanding of these flows is important when designing doors to further reduce such containment failures. Experiments and Computational Fluid Dynamics (CFD) modelling, by using Large-Eddy Simulation (LES) flow solver, were used to study airflow patterns in a full-scale mock-up, consisting of a sliding door separating two identical rooms (i.e. one isolation room attached to an antechamber). A single sliding door open/ hold-open/ closing cycle was studied. Additional variables included human passage through the doorway and imposing a temperature difference between the two rooms. The general structures of computationally-simulated flow features were validated by comparing the results to smoke visualizations of identical full-scale experimental set-ups. It was found that without passage the air volume leakage across the doorway was first dominated by vortex shedding in the wake of the door, but during a prolonged hold-open period a possible temperature difference soon became the predominant driving force. Passage generates a short and powerful pulse of leakage flow rate even if the walker stops to wait for the door to open. supplementary material is available in the online version of this article at 10.1007/s12273-017-0422-8.

Keywords
CFD simulation LES isolation room smoke visualization tracer gas
作者与单位
共 4 位作者,点击展开单位 / ORCID
Saarinen Pekka
1Finnish Institute of Occupational Health, Turku, Finland. | 2Turku University of Applied Sciences, Turku, Finland.
Kalliomäki Petri
1Finnish Institute of Occupational Health, Turku, Finland. | 2Turku University of Applied Sciences, Turku, Finland.
Koskela Hannu
1Finnish Institute of Occupational Health, Turku, Finland. | 2Turku University of Applied Sciences, Turku, Finland.
Tang Julian W
3Leicester Royal Infirmary, University Hospitals Leicester, Leicester, UK. | 4Infection, Immunity and Inflammation, University of Leicester, Leicester, UK.
Article Info
Journal
Building simulation
Abbr.
Build Simul
ISSN
1996-3599
Published
2018-00-00
电子出版
2017-00-06
页码
585-596
Language
English
Country/Region
China
NLM ID
101677932
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]