Home LiteratureArticle Details
PMID: 32287967 Published · ppublish English Journal Article

Wind tunnel tests of inter-flat pollutant transmission characteristics in a rectangular multi-storey residential building, part A: Effect of wind direction.

Building and environment ·Vol. 108 ·2016-11-01 ·页码 159-170

Mu D, Gao N, Zhu T

Abstract

The inter-flat dispersion of hazardous air pollutants in residential built environment has become a growing concern, especially in crowed urban areas. The purpose of present study is to investigate the wind induced air pollutant transmission and cross contamination routes in typical buildings. In this paper, a series of experiments was carried out in a boundary layer wind tunnel using a 1:30 scaled model that represented the typical configuration of rectangular multi-storey residential buildings in Shanghai. Sulfur hexafluoride (SF6) was employed as tracer gas in the wind tunnel tests. The conditions under two ventilation modes, i.e. single-sided natural ventilation and cross natural ventilation, were compared. The tracer gas concentration distributions under four approaching wind angles were monitored and analyzed. Computational Fluid Dynamics (CFD) method was adopted to assist in analyzing airflow patterns. The experiment results elucidated that in the two ventilation scenarios, both of the vertical and horizontal inter-flat airborne transmission could proceed. The wind direction played a key role on the pollutant concentration distribution. Compared with the single-sided ventilation mode, cross ventilation could weaken the air pollutant dispersion along the vertical direction when the contamination source was on the windward or on the leeward unit. When the wind blowing parallelly to the source unit window, namely the source room was on the sideward, cross ventilation would not suppress the vertical transport on one hand, but reinforce the horizontal transmission on the other hand. The study is helpful for the analysis of infection risk of respiratory diseases in the residential buildings.

Keywords
Gaseous pollutant Multi-storey residential buildings Tracer gas Wind tunnel test
作者与单位
共 3 位作者,点击展开单位 / ORCID
Mu Di
School of Mechanical Engineering, Tongji University, Shanghai, China.
Gao Naiping
School of Mechanical Engineering, Tongji University, Shanghai, China.
Zhu Tong
School of Mechanical Engineering, Tongji University, Shanghai, China.
Article Info
Journal
Building and environment
Abbr.
Build Environ
ISSN
0360-1323
Published
2016-11-01
电子出版
2016-00-30
页码
159-170
Language
English
Country/Region
England
NLM ID
101562928
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]