Influence of ceiling fan's speed and direction on efficacy of upperroom, ultraviolet germicidal irradiation: Experimental.

Building and environment ·Vol. 92 ·2015-10-00 ·页码 756-763

Rudnick SN, McDevitt JJ, Hunt GM, Stawnychy MT, Vincent RL, Brickner PW

Abstract

Increasing a ceiling fan's speed from its lowest setting of 61 rpm, which resulted in 0.77 m3/s of airflow, to its highest setting of 176 rpm, which resulted in 2.5 m3/s of airflow, or having the fan blow either upward or downward had no statistically significant effect on the efficacy of upper-room ultraviolet germicidal irradiation (UVGI). This outcome suggests that air circulation due to the ceiling fan was sufficient and that any additional increase would not improve efficacy. Numerous experimental studies on upper-room UVGI in which fans were used to provide air mixing have been published. However, none have quantified the air movement produced by these fans or described their tests in sufficient detail to allow results to be compared to predictions using computational fluid dynamics (CFD). The present work provides the required information. In addition to the usual boundary conditions needed for CFD, we made experimental measurements of UV susceptibility of the microorganisms used in the upper-room UVGI tests. We measured UV susceptibilities for Mycobacterium parafortuitum and Bacillus atrophaeus spores to be 0.074 and 0.018 m2/J, respectively. In a previous publication, we reported the spatial distribution of fluence rate, which is also needed for predicting efficacy from CFD. In a companion paper referred to as Part II, upper-room UVGI efficacy was predicted by both Eulerian and Lagrangian CFD and compared to the experimental results from the present study.

Keywords
Airborne infection control Computational fluid dynamics Tuberculosis control UV susceptibility of bacteria UVGI (or ultraviolet germicidal irradiation)
作者与单位
共 6 位作者,点击展开单位 / ORCID
Rudnick S N
Department of Environmental Health, Harvard School of Public Health, 665 Huntington Avenue, Boston, MA 02115, USA.
McDevitt J J
Department of Environmental Health, Harvard School of Public Health, 665 Huntington Avenue, Boston, MA 02115, USA.
Hunt G M
Department of Environmental Health, Harvard School of Public Health, 665 Huntington Avenue, Boston, MA 02115, USA.
Stawnychy M T
Department of Environmental Health, Harvard School of Public Health, 665 Huntington Avenue, Boston, MA 02115, USA.
Vincent R L
Department of Medicine, Section of General Internal Medicine, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, Box 1087, New York, NY 10029, USA.
Brickner P W
Department of Medicine, Section of General Internal Medicine, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, Box 1087, New York, NY 10029, USA.
Article Info
Journal
Building and environment
Abbr.
Build Environ
ISSN
0360-1323
Published
2015-10-00
电子出版
2014-00-12
页码
756-763
Language
English
Country/Region
England
NLM ID
101562928
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]