Design of custom-made navigational template of femoral head and pilot research in total hip resurfacing arthroplasty.

BMC surgery ·Vol. 20 ·No. 1 ·2020-06-30

Liang J, Zhao Y, Gao X, Fang X, Xu Y, Lu S

Abstract

To develop a novel custom-made navigational template for accurate prosthesis implantation in total hip resurfacing arthroplasty (THRA) by computer-aided technology. The template was produced based on data preoperatively acquired from computed tomography (CT) scan. The position of the drill guide was obtained according to the anatomical axis of the femoral neck which was defined by the point of the femoral head center and another point of the femoral neck center. The final direction of the drill guide was confirmed by a valgus angle. The surface of the template was constructed based on the inverse of the femoral neck surface. Then the template was made of acrylate resin by using rapid prototyping (RP) technique. Finally, all the templates were verified in 17 cadavers arranged for THRA and postoperative medical images were employed to evaluate the accuracy and validity of the template. The templates had achieved a high fitting with the femoral neck surface, and there were no guide failures. Postoperative evaluation revealed that the Kirschner-wires pass through the center of the femoral head and femoral neck, presenting a relative expected and acceptable valgus angle to the central axis of the femoral neck. The lateral offset showed the relative valgus angle achieved as expected, the horizontal offset showed that no obvious antero-posterior deviation occured. The comparison between the preoperative Neck-shaft angle (NSA) and the postoperative Stem-shaft angle (SSA) showed there is no significant difference(P > 0.05). The novel custom-made navigational template of femoral head can effectively assist surgeons for accurately implanting the femoral head components to the desired position in THRA.

Keywords
Anatomical axis of the femoral neck Computer assisted surgery Custom-made navigational template Rapid prototyping Total hip resurfacing Arthroplasty
Article Info
Journal
BMC surgery
Abbr.
BMC Surg
ISSN
1471-2482
Corresponding email
Published
2020-06-30
Language
English
Country/Region
England
NLM ID
100968567
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]