Home LiteratureArticle Details
PMID: 32983315 Published · ppublish English Journal Article

Model-Based Design and Optimization of Blood Oxygenators.

Journal of medical devices ·Vol. 14 ·No. 4 ·2020-12-01 ·页码 041001

He G, Zhang T, Zhang J, Griffith BP, Wu ZJ

Abstract

Blood oxygenators, also known as artificial lungs, are widely used in cardiopulmonary bypass surgery to maintain physiologic oxygen (O2) and carbon dioxide (CO2) levels in blood, and also serve as respiratory assist devices to support patients with lung failure. The time- and cost-consuming method of trial and error is initially used to optimize the oxygenator design, and this method is followed by the introduction of the computational fluid dynamics (CFD) that is employed to reduce the number of prototypes that must be built as the design is optimized. The CFD modeling method, while having progress in recent years, still requires complex three-dimensional (3D) modeling and experimental data to identify the model parameters and validate the model. In this study, we sought to develop an easily implemented mathematical models to predict and optimize the performance (oxygen partial pressure/saturation, oxygen/carbon dioxide transfer rates, and pressure loss) of hollow fiber membrane-based oxygenators and this model can be then used in conjunction with CFD to reduce the number of 3D CFD iteration for further oxygenator design and optimization. The model parameters are first identified by fitting the model predictions to the experimental data obtained from a mock flow loop experimental test on a mini fiber bundle. The models are then validated through comparing the theoretical results with the experimental data of seven full-size oxygenators. The comparative analysis show that the model predictions and experimental results are in good agreement. Based on the verified models, the design curves showing the effects of parameters on the performance of oxygenators and the guidelines detailing the optimization process are established to determine the optimal design parameters (fiber bundle dimensions and its porosity) under specific system design requirements (blood pressure drop, oxygen pressure/saturation, oxygen/carbon dioxide transfer rates, and priming volume). The results show that the model-based optimization method is promising to derive the optimal parameters in an efficient way and to serve as an intermediate modeling approach prior to complex CFD modeling.

Keywords
artificial lung empirical model hollow fiber membrane oxygen transfer porous media
作者与单位
共 5 位作者,点击展开单位 / ORCID
He Ge
Department of Surgery, School of Medicine, University of Maryland, Baltimore, MD 21201.
Zhang Tao
Abiomed, Inc., 22 Cherry Hill Dr., Danvers, MA 01923.
Zhang Jiafeng
Department of Surgery, School of Medicine, University of Maryland, Baltimore, MD 21201.
Griffith Bartley P
Department of Surgery, School of Medicine, University of Maryland, Baltimore, MD 21201.
Wu Zhongjun J
Department of Surgery, School of Medicine, University of Maryland, 10 South Pine Street, Baltimore, MD 21201; Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742.
Article Info
Journal
Journal of medical devices
Abbr.
J Med Device
ISSN
1932-6181
Published
2020-12-01
电子出版
2020-00-31
页码
041001
Language
English
Country/Region
United States
NLM ID
101299321
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]