Home LiteratureArticle Details
PMID: 33261729 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't

Evaluation of the ocular fluid dynamic effects on intraocular magnesium-based device: A comparison between CFD and FSI approaches.

Medical engineering & physics ·Vol. 86 ·2020-00-00 ·页码 20-28

Ferroni M, De Gaetano F, Cereda MG, Boschetti F

Abstract

Magnesium is an essential element for the ocular functions and used for the realization of medical devices due to its low corrosion resistance, bioresorbable nature and biocompatibility. Wet age-related macular degeneration is one of the main causes of blindness with patients treated by intravitreal injections of inhibitor drugs. According to the need to reduce the number of injections, the development of new drug delivery devices able to extend the therapeutical outcomes is mandatory and magnesium can be considered as a promising candidate. The aim of the work concerns the evaluation of the ocular fluid dynamic role on a magnesium-based device placed in the vitreous chamber. Particularly, the fluid-induced shear stress field on the surfaces in contact with the liquefied vitreous was studied. Both computational fluid dynamic and fluid-structure interaction approaches were proposed and then compared. Saccadic motion was implemented to recreate the vitreous fluid dynamics. High changes in terms of fluid-induced shear stress field varying the CFD and FSI numerical approaches and kinematic parameters of the saccadic function can be noticed. The comparison between CFD and FSI approaches showed minor significant differences and both implementations suggested the possibility to obtain a uniform and controlled corrosion of the device.

Keywords
Computational fluid dynamics Drug delivery Fluid-structure interaction Magnesium Numerical modelling
MeSH 主题词
Computer Simulation Humans Hydrodynamics Magnesium Pharmaceutical Preparations Stress, Mechanical
化学物质
Pharmaceutical Preparations Magnesium
作者与单位
共 4 位作者,点击展开单位 / ORCID
Ferroni Marco
LaBS, Chemistry Materials and Chemical Engineering Department "Giulio Natta", Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy; MgShell S.r.l., Milan, Italy. Electronic address: [email protected].
De Gaetano Francesco
LaBS, Chemistry Materials and Chemical Engineering Department "Giulio Natta", Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy; MgShell S.r.l., Milan, Italy.
Cereda Matteo Giuseppe
Eye Clinic, Department of Biomedical and clinical science "Luigi Sacco", Sacco Hospital, University of Milan, Via G.B. Grassi 74, 20157 Milan, Italy.
Boschetti Federica
LaBS, Chemistry Materials and Chemical Engineering Department "Giulio Natta", Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy.
Article Info
Journal
Medical engineering & physics
Abbr.
Med Eng Phys
ISSN
1873-4030
Corresponding email
Published
2020-00-00
电子出版
2020-00-07
页码
20-28
Language
English
Country/Region
England
NLM ID
9422753
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]