Home LiteratureArticle Details
PMID: 33422725 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't

Impact of prosthetic mitral valve orientation on the ventricular flow field: Comparison using patient-specific computational fluid dynamics.

Journal of biomechanics ·Vol. 116 ·2021-00-12 ·页码 110209

Lantz J, Bäck S, Carlhäll CJ, Bolger A, Persson A, Karlsson M, Ebbers T

Abstract

Significant mitral valve regurgitation creates progressive adverse remodeling of the left ventricle (LV). Replacement of the failing valve with a prosthesis generally improves patient outcomes but leaves the patient with non-physiological intracardiac flow patterns that might contribute to their future risk of thrombus formation and embolism. It has been suggested that the angular orientation of the implanted valve might modify the postoperative distortion of the intraventricular flow field. In this study, we investigated the effect of prosthetic valve orientation on LV flow patterns by using heart geometry from a patient with LV dysfunction and a competent native mitral valve to calculate intracardiac flow fields with computational fluid dynamics (CFD). Results were validated using in vivo 4D Flow MRI. The computed flow fields were compared to calculations following virtual implantation of a mechanical heart valve oriented in four different angles to assess the effect of leaflet position. Flow patterns were visualized in long- and short-axes and quantified with flow component analysis. In comparison to a native valve, valve implantation increased the proportion of the mitral inflow remaining in the basal region and further increased the residual volume in the apical area. Only slight changes due to valve orientation were observed. Using our numerical framework, we demonstrated quantitative changes in left ventricular blood flow due to prosthetic mitral replacement. This framework may be used to improve design of prosthetic heart valves and implantation procedures to minimize the potential for apical flow stasis, and potentially assist personalized treatment planning.

Keywords
4D flow CT Computational fluid dynamics Computed tomography Mitral valve Virtual implantation
MeSH 主题词
Heart Valve Prosthesis Heart Valve Prosthesis Implantation Heart Ventricles/diagnostic imaging Humans Hydrodynamics Mitral Valve/surgery
作者与单位
共 7 位作者,点击展开单位 / ORCID
Lantz Jonas
Division of Cardiovascular Medicine, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden; Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.
Bäck Sophia
Division of Cardiovascular Medicine, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden; Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.
Carlhäll Carl-Johan
Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden; Department of Clinical Physiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
Bolger Ann
Department of Clinical Physiology in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden; Department of Medicine, University of California, San Francisco, United States.
Persson Anders
Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden; Division of Radiology, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
Karlsson Matts
Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden; Division of Applied Thermodynamics and Fluid Mechanics, Department of Management and Engineering, Linköping University, Sweden.
Ebbers Tino
Division of Cardiovascular Medicine, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden; Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden. Electronic address: [email protected].
Article Info
Journal
Journal of biomechanics
Abbr.
J Biomech
ISSN
1873-2380
Corresponding email
Published
2021-00-12
电子出版
2020-00-28
页码
110209
Language
English
Country/Region
United States
NLM ID
0157375
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]