Home LiteratureArticle Details
PMID: 33814673 Published · ppublish English Journal Article

Challenges in hemodynamics assessment in complex neurovascular geometries using computational fluid dynamics and benchtop flow simulation in 3D printed patient specific phantoms.

Proceedings of SPIE--the International Society for Optical Engineering ·Vol. 11600 ·2021-02-00

Paccione E, Ionita CN

Abstract

Complex hemodynamics assessments, as those related to carotid stenosis, are not always easily straightforward due to multifaceted challenges presented by the collateral flow in the Circle of Willis (CoW) and brain flow autoregulation. Advanced computational and benchtop methods to investigate hemodynamics aspects related to such complex flows are often used, however both have limitations and could lead to results which may diverge. In this study we investigated these aspects by performing correlated computational fluid dynamics (CFD) simulations and benchtop experiments in patient specific 3D printed phantoms. To investigate the flow in patients with carotid stenosis, we built two patient specific phantoms which contained the arterial lesion of interest, all main arteries leading to the brain, the CoW and main arteries branching from it. Each phantom was connected to a generic aortic arch. A programmable pump was connected and flow parameters were measured proximal and distal to the lesion and the contralateral arteries. The patient 3D geometry was used to perform a set of CFD simulations where inflow boundary conditions matched the experimental ones. Flow conditions were recorded at the same locations as the experimental setup. Further exploration into the translation from experimental to CFD was also performed by customizing vascular segmentation and physically manipulating arterial compliance properties. We initially observed significant differences between the CFD recordings and the experimental setup. Most of the differences were due to changes in phantom geometry when subjected to physiological pressures and simplistic outflow boundary conditions in the CFD simulations which do not account for pulsatility and nonlinear phenomena. Further work confirms the need for dynamic mesh behavior within CFD simulations attempting to computationally mimic 3D-printed benchtop experiments. Additionally, CFD simulation may benefit from considering geometry specific to a 3D-printed vascular phantom.

Keywords
3D-printing CFD carotid stenosis hemodynamics stroke
作者与单位
共 2 位作者,点击展开单位 / ORCID
Paccione Eric
University Dept. of Biomedical Engineering, University at Buffalo, Buffalo, NY.
Ionita Ciprian N
University Dept. of Biomedical Engineering, University at Buffalo, Buffalo, NY. | Canon Stroke and Vascular Research Center, Buffalo, NY.
Article Info
Journal
Proceedings of SPIE--the International Society for Optical Engineering
Abbr.
Proc SPIE Int Soc Opt Eng
ISSN
0277-786X
Published
2021-02-00
电子出版
2021-00-15
Language
English
Country/Region
United States
NLM ID
101524122
基金资助
NIBIB NIH HHS · R01 EB030092 · United States
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]