Home LiteratureArticle Details
PMID: 3399430 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't

Doppler-derived cardiac output in healthy newborn infants in relation to physiological patency of the ductus arteriosus.

Pediatric cardiology ·Vol. 9 ·No. 2 ·1988-00-00 ·Pages 79-83

Hirsimäki H, Kero P, Wanne O, Erkkola R, Makoi Z

Abstract

Noninvasive Doppler-derived cardiac output was measured with the pulsed Doppler method in 22 healthy newborns during their first four days of life. Maximal blood flow velocity in the aorta was measured with the Doppler ultrasound method. The mean Doppler-derived cardiac output was 273 +/- 59 ml/min/kg. Ductal left-to-right shunting was also determined and then graded according to the flow in the main pulmonary artery. The mean Doppler-derived cardiac output was 301 +/- 61 ml/min/kg when there was a moderate ductal left-to-right shunt, 266 +/- 59 ml/min/kg when the shunting was mild, and 260 +/- 53 ml/min/kg when there was no shunting ductus. The Doppler-derived cardiac output was significantly higher when there was a moderate left-to-right shunt than without such shunting. This method seems to be a useful approach in monitoring the cardiac function of newborns without unduly disturbing their condition. Normal values on Doppler-derived cardiac output have to be judged in relation to the magnitude of ductal left-to-right shunt.

MeSH Terms
Cardiac Output Ductus Arteriosus/physiopathology Ductus Arteriosus, Patent/physiopathology Echocardiography Heart Ventricles/physiopathology Humans Infant, Newborn Reference Values Stroke Volume
Authors & Affiliations
5 authors, click to expand affiliations / ORCID
Hirsimäki H
Department of Pediatrics, Turku University Hospital, Finland.
Kero P
Wanne O
Erkkola R
Makoi Z
References (18)
18 references, click to expand
  1. Assessment of cardiac output by the Doppler ultrasound technique alone.
    Br Heart J. 1985 Feb;53(2):123-9 PMID: 3881107
  2. Noninvasive measurement of cardiac output in healthy preterm and term newborn infants.
    Am J Perinatol. 1984 Jan;1(2):148-51 PMID: 6518060
  3. Noninvasive measurement of cardiac output by continuous-wave Doppler echocardiography: initial experience and review of the literature.
    Mayo Clin Proc. 1984 Jul;59(7):484-9 PMID: 6738114
  4. Pulsed Doppler echocardiographic determination of time of ductal closure in normal newborn infants.
    J Pediatr. 1981 Mar;98(3):443-8 PMID: 7205459
  5. Noninvasive pulsed Doppler determination of cardiac output in neonates and children.
    J Pediatr. 1982 Jul;101(1):46-50 PMID: 7086622
  6. The behavioural states of the newborn infant (a review).
    Brain Res. 1974 Aug 16;76(2):185-212 PMID: 4602352
  7. Determination of cardiac output by Doppler echocardiography.
    Br Heart J. 1984 Jan;51(1):54-60 PMID: 6689921
  8. Trancutaneous determination of aortic blood-flow velocities in man.
    Am Heart J. 1975 May;89(5):605-12 PMID: 123407
  9. Doppler flow characteristics in the main pulmonary artery and the LA/Ao ratio before and after ductal closure in healthy newborns.
    Pediatr Cardiol. 1982;3(2):99-104 PMID: 7155955
  10. How far is the cardiac output?
    Lancet. 1984 Nov 3;2(8410):1025-7 PMID: 6149404
  11. Cardiac output in infants of insulin-dependent diabetic mothers.
    J Pediatr. 1985 Jul;107(1):109-14 PMID: 4009327
  12. Noninvasive Doppler determination of cardiac output in man. Clinical validation.
    Circulation. 1983 Mar;67(3):593-602 PMID: 6821902
  13. Effect of patent ductus arteriosus on left ventricular output in premature infants.
    J Pediatr. 1983 May;102(5):754-7 PMID: 6842335
  14. Cardiac output determination in the neonate.
    J Pediatr. 1983 May;102(5):709-11 PMID: 6842325
  15. Measurement of instantaneous blood-flow velocity in the human aorta using pulsed Doppler ultrasound.
    Cardiovasc Res. 1982 Jan;16(1):26-33 PMID: 7060059
  16. Neonatal cardiac output measurement using pulsed Doppler ultrasound.
    Clin Perinatol. 1985 Feb;12(1):101-27 PMID: 3884219
  17. Aortic blood velocity measurement in healthy adults using a simple ultrasound technique.
    Cardiovasc Res. 1983 Feb;17(2):75-80 PMID: 6871901
  18. Combined doppler and phased-array echocardiographic estimation of cardiac output.
    Circulation. 1981 Feb;63(2):388-92 PMID: 7449060
Article Info
Journal
Pediatric cardiology
Abbr.
Pediatr Cardiol
ISSN
0172-0643
Published
1988-00-00
Pages
79-83
Language
English
Region
United States
NLM ID
8003849
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]