The influence of airtightness on contaminant spread in MURBs in cold climates.

Building simulation ·2021-05-15 ·页码 1-16

Mckeen P, Liao Z

Abstract

Tall buildings in cold climates have unique challenges in maintaining indoor air quality due to stack effect. During the heating season, interior air buoyancy creates large pressure differentials in vertical shafts that can drive airflow from lower floors into upper floors. This pressure differential can result in the spread of contaminants throughout a building. Most recently, concern over COVID-19 has increased attention to the potential spread of airborne diseases in densely populated buildings. For many multi-unit residential buildings, suite ventilation has traditionally relied upon fresh air supplied through a mechanically pressurized corridor. In cold climates, large pressure differentials created by stack-effect can reduce the effectiveness of this approach. Multizone and CFD simulations are employed to analyze airflow and contaminant spread due to stack effect. Simulations are conducted on an idealized model of a 10-storey building using a range of experimentally derived airtightness parameters. Simulations demonstrate stack effect can reduce corridor ventilation to suites and even reverse the airflow for leakier buildings. Reduced airflow to suites can result in the accumulation of contaminants. Reversal of the airflow can allow contaminants from a suite to spread throughout the building. Contaminant spread is illustrated as a function of mechanical ventilation, building airtightness, and ambient temperatures. Strategies to reduce the influence of stack effect on mechanically pressurized corridors are discussed.

Keywords
MURBs ventilation contamination spread stack effect
作者与单位
共 2 位作者,点击展开单位 / ORCID
Mckeen Philip
Department of Architectural Science, Ryerson University, Toronto, M5B 2K3 Canada.
Liao Zaiyi
Department of Architectural Science, Ryerson University, Toronto, M5B 2K3 Canada.
Article Info
Journal
Building simulation
Abbr.
Build Simul
ISSN
1996-3599
Published
2021-05-15
电子出版
2021-00-15
页码
1-16
Language
English
Country/Region
China
NLM ID
101677932
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]