Home LiteratureArticle Details
PMID: 34303498 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't

Impact of stent malapposition on intracoronary flow dynamics: An optical coherence tomography-based patient-specific study.

Medical engineering & physics ·Vol. 94 ·2021-00-00 ·页码 26-32

Wei L, Wang J, Chen Q, Li Z

Abstract

Percutaneous coronary intervention with stent implantation has emerged as a popular approach to treat coronary artery stenosis. Stent malapposition (SM), also referred as incomplete stent apposition, could reduce stent tissue coverage and hence increase the risk of late stent thrombosis. The objective of this study was to investigate the impact of SM on intracoronary flow dynamics by combining optical coherence tomography (OCT) image-based model reconstruction and computational analysis. Firstly, a stenosed coronary artery model was reconstructed from OCT and angiography imaging data of a patient. Two structural analyses were carried out to simulate two types of coronary artery stent implantations: a fully-apposed (FA) case and a SM case. Then, based on the two deformed coronary geometries, two computational fluid dynamics (CFD) analyses were performed to evaluate the differences of hemodynamic metrics between the FA and the SM cases, including wall shear stress (WSS), time-averaged WSS (TWSS), oscillatory shear index (OSI), WSS gradient (WSSG), time-averaged WSSG (TWSSG), and relative residence time (RRT). The results indicated that maximum flow velocity was higher in the SM case than that of the FA case, due to the incomplete expansion of the stent and artery. Moreover, the SM case had a lower percentage of areas of adverse WSS (< 0.5 Pa) and RRT (> 10/Pa) but a higher percentage of areas of adverse OSI (> 0.1) and WSSG (> 5000 Pa/m). Specifically, the differences of OSI, WSSG, and RRT between the two cases were relatively small. It was suggested that SM might not be responsible for negative hemodynamic metrics which would further result in stent thrombosis on the basis of the present specific model.

Keywords
Computational fluid dynamics (CFD) Coronary artery Hemodynamics Percutaneous coronary intervention Stent malapposition
MeSH 主题词
Computer Simulation Coronary Vessels/diagnostic imaging,surgery Hemodynamics Humans Models, Cardiovascular Stents Tomography, Optical Coherence
作者与单位
共 4 位作者,点击展开单位 / ORCID
Wei Lingling
Biomechanics Laboratory, School of Biological Science & Medical Engineering, Southeast University, Nanjing 210096, PR China.
Wang Jiaqiu
School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane QLD 4001, Australia.
Chen Qiang
Biomechanics Laboratory, School of Biological Science & Medical Engineering, Southeast University, Nanjing 210096, PR China. Electronic address: [email protected].
Li Zhiyong
Biomechanics Laboratory, School of Biological Science & Medical Engineering, Southeast University, Nanjing 210096, PR China; School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane QLD 4001, Australia. Electronic address: [email protected].
Article Info
Journal
Medical engineering & physics
Abbr.
Med Eng Phys
ISSN
1873-4030
Published
2021-00-00
电子出版
2021-00-08
页码
26-32
Language
English
Country/Region
England
NLM ID
9422753
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]