Home LiteratureArticle Details
PMID: 34544050 Published · epublish English Journal Article Research Support, Non-U.S. Gov't

Prediction of potential passive exposure from commercial electronic nicotine delivery systems using exhaled breath analysis and computational fluid dynamic techniques.

Journal of breath research ·Vol. 15 ·No. 4 ·2021-00-05

Oldham MJ, Bailey PC, Castro N, Lang Q, Salehi A, Rostami AA

Abstract

Use of computational fluid dynamic (CFD) modeling to predict temporal and spatial constituent exposure for non-electronic nicotine delivery systems (ENDS) users (passive exposure) provides a more efficient methodology compared to conducting actual exposure studies. We conducted a clinical study measuring exhaled breath concentrations of glycerin, propylene glycol, nicotine, benzoic acid, formaldehyde, acetaldehyde, acrolein, menthol and carbon monoxide from use of eight different commercial ENDS devices and a non-menthol and menthol cigarette. Because baseline adjusted levels of other constituents were not consistently above the limit of detection, the mean minimum and maximum per puff exhaled breath concentrations (N= 20/product) of glycerin (158.7-260.9µg), propylene glycol (0.941-3.58µg), nicotine (0.10-1.06µg), and menthol (0.432-0.605µg) from use of the ENDS products were used as input parameters to predict temporal and spatial concentrations in an environmental chamber, office, restaurant, and car using different ENDS use scenarios. Among these indoor locations and ENDS use scenarios, the car with closed windows resulted in the greatest concentrations while opening the car windows produced the lowest concentrations. The CFD predicted average maximum glycerin and propylene glycol concentration ranged from 0.25 to 1068µg m-3and 1.5 pg m-3to 13.56µg m-3,respectively. For nicotine and menthol the CFD predicted maximum concentration ranged from 0.16 pg m-3to 4.02µg m-3and 0.068 pg m-3to 2.43µg m-3, respectively. There was better agreement for CFD-predicted nicotine concentrations than glycerin and propylene glycol with published reports highlighting important experimental and computational variables. Maximum measured nicotine levels from environmental tobacco smoke in offices, restaurants, and cars exceeded our maximum average CFD predictions by 7-97 times. For all the measured exhaled breath constituents and CFD predicted constituents, except for propylene glycol and glycerin, concentrations were less from use of ENDS products compared to combustible cigarettes. NCT number: NCT04143256.

Keywords
electronic nicotine delivery systems exhaled breath glycerin menthol nicotine propylene glycol
MeSH 主题词
Breath Tests Electronic Nicotine Delivery Systems Humans Hydrodynamics Nicotine Tobacco Smoke Pollution
化学物质
Tobacco Smoke Pollution Nicotine
作者与单位
共 6 位作者,点击展开单位 / ORCID
Oldham Michael J ORCID
Product Stewardship, JUUL Labs, Washington, DC, United States of America.
Bailey Patrick C
Scientific Affairs, JUUL Labs, Washington, DC, United States of America.
Castro Nicolas
Modelling and Simulation, Altria Client Services, LLC, Richmond, VA, United States of America.
Lang Qiwei
Regulatory Sciences, JUUL Labs, Washington, DC, United States of America.
Salehi Armin
Modelling and Simulation, Altria Client Services, LLC, Richmond, VA, United States of America.
Rostami Ali A ORCID
Modelling and Simulation, Altria Client Services, LLC, Richmond, VA, United States of America.
Article Info
Journal
Journal of breath research
Abbr.
J Breath Res
ISSN
1752-7163
Published
2021-00-05
电子出版
2021-00-05
Language
English
Country/Region
England
NLM ID
101463871
数据资源
ClinicalTrials.gov
NCT04143256
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]