Effective ventilation and air disinfection system for reducing coronavirus disease 2019 (COVID-19) infection risk in office buildings.

Sustainable cities and society ·Vol. 75 ·2021-12-00 ·页码 103408

Srivastava S, Zhao X, Manay A, Chen Q

Abstract

During the COVID-19 pandemic, an increasing amount of evidence has suggested that the virus can be transmitted through the air inside buildings. The ventilation system used to create the indoor environment would facilitate the transmission of the airborne infectious diseases. However, the existing ventilation systems in most buildings cannot supply sufficient clean outdoor air for diluting the virus concentration. To reduce the airborne infection risk and minimize energy consumption, especially in existing buildings with well-mixed ventilation systems, this investigation used an ultraviolet-C (UV-C) air disinfection device (Rheem's third generation products, RM3) with 99.9% disinfection efficiency to clean air carrying the COVID-19 virus (severe acute respiratory syndrome coronavirus 2, SARS-CoV-2) which could help promote environmental sustainability and create healthy cities. This investigation assessed the impact of the RM3 UV-C units on the infection risk, the number of RM3 UV-C units required, and the strategy for decreasing the infection risk, with the use of computational-fluid-dynamics (CFD) numerical simulations. An actual office building with a combination of individual offices and workstations was selected as an example for the research. According to the numerical results, the best strategy would be to use a combination of 100% outside air and UV-C in heating, ventilation and air-conditioning (HVAC) ducts with air disinfected by the RM3 UV-C units. The infection risk in the office building could thus be reduced to a negligible level. These findings could provide theoretical basis and engineering application basis for COVID-19 epidemic prevention and control.

Keywords
Airborne transmission CFD COVID-19 Indoor environment Infection risk Ultraviolet-C disinfection device
作者与单位
共 4 位作者,点击展开单位 / ORCID
Srivastava Shubham
Water Heater Division, Rheem Manufacturing Company Inc, Atlanta, GA 30328, USA.
Zhao Xingwang
School of Energy and Environment, Southeast University, Nanjing 210096, China.
Manay Ati
Water Heater Division, Rheem Manufacturing Company Inc, Atlanta, GA 30328, USA.
Chen Qingyan
School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA.
Article Info
Journal
Sustainable cities and society
Abbr.
Sustain Cities Soc
ISSN
2210-6715
Published
2021-12-00
电子出版
2021-00-29
页码
103408
Language
English
Country/Region
Netherlands
NLM ID
101735304
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.