Home LiteratureArticle Details
PMID: 34772847 Published · aheadofprint English Journal Article

Characterization and Development of Universal Ventricular Assist Device: Computational Fluid Dynamics Analysis of Advanced Design.

Goodin MS, Showalter MS, Horvath DJ, Kuban BD, Flick CR, Polakowski AR, Fukamachi K, Karimov JH

Abstract

We are developing a universal, advanced ventricular assist device (AVAD) with automatic pressure regulation suitable for both left and right ventricular support. The primary goal of this computational fluid dynamics (CFD) study was to analyze the biventricular performance of the AVAD across its wide range of operating conditions. An AVAD CFD model was created and validated using in vitro hydraulic performance measurements taken over conditions spanning both left ventricular assist device (LVAD) and right ventricular assist device (RVAD) operation. Static pressure taps, placed throughout the pump, were used to validate the CFD results. The CFD model was then used to assess the change in hydraulic performance with varying rotor axial positions and identify potential design improvements. The hydraulic performance was simulated and measured at rotor speeds from 2,300 to 3,600 revolutions/min and flow rates from 2.0 to 8.0 L/min. The CFD-predicted hydraulic pressure rise agreed well with the in vitro measured data, within 6.5% at 2300 rpm and within 3.5% for the higher rotor speeds. The CFD successfully predicted wall static pressures, matching experimental values within 7%. High degree of similarity and circumferential uniformity in the pump's flow fields were observed over the pump operation as an LVAD and an RVAD. A secondary impeller axial clearance reduction resulted in a 10% decrease in peak flow residence time and lower static pressures on the secondary impeller. These lower static pressures suggest a reduction in the upwards rotor forces from the secondary impeller and a desired increase in the pressure sensitivity of the pump. The CFD analyses supported the feasibility of the proposed AVAD's use as an LVAD or an RVAD, over a wide range of operating conditions. The CFD results demonstrated the operability of the pump in providing the desired circumferential flow similarity over the intended range of flow/speed conditions and the intended functionality of the AVAD's automated pressure regulation.

作者与单位
共 8 位作者,点击展开单位 / ORCID
Goodin Mark S
SimuTech Group, Hudson, Ohio SimuTech Group, Huntsville, Alabama R1 Engineering LLC, Euclid Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, Ohio, USA.
Showalter Michael S
Horvath David J
Kuban Barry D
Flick Christine R
Polakowski Anthony R
Fukamachi Kiyotaka
Karimov Jamshid H
Article Info
Journal
ASAIO journal (American Society for Artificial Internal Organs : 1992)
Abbr.
ASAIO J
ISSN
1538-943X
Published
2021-11-10
电子出版
2021-00-10
Language
English
Country/Region
United States
NLM ID
9204109
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]