Home LiteratureArticle Details
PMID: 34828546 Published · epublish English Journal Article

Infection Control Improvement of a Negative-Pressurized Pediatric Intensive Care Unit.

Healthcare (Basel, Switzerland) ·Vol. 9 ·No. 11 ·2021-11-04

Wang F, Permana I, Chaerasari C, Panigrahi B, Rakshit D

Abstract

The COVID-19 pandemic caused by the novel SARS-CoV-2 virus raises alarming concern around the healthcare facilities due to the significant increase in patient inflow. Negative-pressurized isolation rooms have been utilized in various health care facilities to isolate the patients from active community contact. Several studies have highlighted isolation rooms improvement. However, limited knowledge is available regarding the isolation room facilities for pediatric intensive care units (PICU) to accommodate more than one pediatric patient. In this aspect, this study investigates a negative-pressurized isolation facility in PICU with minimal design modifications with the possibility that it can accommodate more than one pediatric patient. The field measurement tests were conducted to ensure the design compliance of Taiwan CDC. Then, computational fluid dynamics (CFD) was further utilized to numerically evaluate the HVAC system role and the ventilation performance towards infection control. A protected air-jet curtain system with a new ventilation layout was proposed through this study to enhance the protection for both pediatric patients and medical staff. The concentration decay was monitored and recorded within 900 s to evaluate the performance. The concentration can be reduced to 504 ppm for case 1, 620 ppm for case 2, 501 ppm for case 3, and 486 ppm for case 4. In addition, the injected bioaerosol particles could be well diluted dealing with two patients presents a good performance. The results revealed that this proposed configuration could feasibly accommodate two patients with a significant contamination control to protect the medical staff and patients.

Keywords
computational fluid dynamics infection control isolation room ventilation performance
作者与单位
共 5 位作者,点击展开单位 / ORCID
Wang Fujen ORCID
Department of Refrigeration, Air Conditioning and Energy Engineering, National Chin-Yi University of Technology, Taichung 411, Taiwan.
Permana Indra ORCID
Graduate Institute of Precision Manufacturing, National Chin-Yi University of Technology, Taichung 411, Taiwan.
Chaerasari Citra
Department of Refrigeration, Air Conditioning and Energy Engineering, National Chin-Yi University of Technology, Taichung 411, Taiwan.
Panigrahi Bivas ORCID
Department of Refrigeration, Air Conditioning and Energy Engineering, National Chin-Yi University of Technology, Taichung 411, Taiwan.
Rakshit Dibakar ORCID
Department of Energy Science and Engineering, Indian Institute of Technology Delhi, New Delhi 110016, India.
Article Info
Journal
Healthcare (Basel, Switzerland)
Abbr.
Healthcare (Basel)
ISSN
2227-9032
Published
2021-11-04
电子出版
2021-00-04
Language
English
Country/Region
Switzerland
NLM ID
101666525
基金资助
Ministry of Science and Technology · MOST 109-2622-E-167-002-CC3
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]