Home LiteratureArticle Details
PMID: 35058026 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't

Evaluation of flow field in the anterior segment during irrigation and aspiration in cataract surgery with three-dimensional computational simulation.

Medical engineering & physics ·Vol. 99 ·2022-00-00 ·页码 103741

Wang Y, Shi X, Wei S, Yue C, Wang Z, Li X

Abstract

To quantitatively analyze the flow field and fluid pressure contour in the anterior segment during the irrigation and aspiration (I/A) procedure by means of computational fluid dynamics (CFD) simulation. Four different models were established combining the irrigation sleeve, aspiration cannula, anterior chamber, and capsule to simulate various scenarios during the coaxial I/A procedure. Commercial CFX software was applied to perform the steady-state simulation with the k-ε turbulence model. The inlet boundary condition was a balanced salt solution with a 100 cm height of pressure, and the mass flow rate boundary condition set at 40 cc/min was applied at the outlet. The four models included the I/A tip located in the middle of the pupillary plane, the capsule equator, and the middle of the posterior capsule. The inlet/outlet pressure at the tip of the I/A cannula was almost the same in the four models. Following ejection into the anterior chamber and capsule bag, the streamline speed rapidly decreased. The pressure in the anterior chamber and capsule bag was approximately 60-70 mmHg. The area on the cornea and capsule closer to the initial streamline of the inlet irrigation possessed larger pressure. The differential pressure on the cornea and capsule was greater when the irrigation orifice directly facing the wall. The pressure varies at different positions in the anterior segment during the I/A procedure. The study suggests that specific precautions are required when the tip moves closer to the wall and the irrigation orifice is directed toward the opposite wall.

Keywords
Cataract Computational fluid dynamics Flow field Irrigation and aspiration
MeSH 主题词
Anterior Chamber Cataract Computer Simulation Humans Hydrodynamics Therapeutic Irrigation/methods
作者与单位
共 6 位作者,点击展开单位 / ORCID
Wang Yuexin
Department of Ophthalmology, Peking University Third Hospital, Beijing, China; Beijing key laboratory of restoration of damaged ocular nerve, Peking University Third Hospital, Beijing, China.
Shi Xiaotian
China Academy of Aerospace Aerodynamics, Beijing, China.
Wei Shanshan
Department of Ophthalmology, Peking University Third Hospital, Beijing, China; Beijing key laboratory of restoration of damaged ocular nerve, Peking University Third Hospital, Beijing, China.
Yue Caiqian
China Academy of Aerospace Aerodynamics, Beijing, China.
Wang Zhenyu
Department of Ophthalmology, Peking University Third Hospital, Beijing, China; Beijing key laboratory of restoration of damaged ocular nerve, Peking University Third Hospital, Beijing, China.
Li Xuemin
Department of Ophthalmology, Peking University Third Hospital, Beijing, China; Beijing key laboratory of restoration of damaged ocular nerve, Peking University Third Hospital, Beijing, China. Electronic address: [email protected].
Article Info
Journal
Medical engineering & physics
Abbr.
Med Eng Phys
ISSN
1873-4030
Corresponding email
Published
2022-00-00
电子出版
2021-00-10
页码
103741
Language
English
Country/Region
England
NLM ID
9422753
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]