Temperature control in Lowicryl K4M and glycol methacrylate during polymerization: is there a low-temperature embedding method?

Journal of microscopy ·Vol. 144 ·No. Pt 2 ·1986-11-00 ·Pages 107-26

Ashford AE, Allaway WG, Gubler F, Lennon A, Sleegers J

Abstract

An apparatus for embedding tissues at resin temperatures down to 228 K is described. By placing thermocouples in the resin the temperature has been monitored during embedding at low temperature with glycol methacrylate (GMA) and Lowicryl K4M. Even in this apparatus with a liquid cooling bath the heat of polymerization is not dissipated and the resin temperature rises. This rise is directly proportional to the resin temperature at the onset of polymerization and is higher in Lowicryl K4M than GMA. The initial resin temperature also affects the time taken for polymerization. The time to the onset of the peak and its duration are both increased as the temperature is lowered. This effect is more pronounced with GMA than Lowicryl K4M and polymerization of GMA is inhibited at the lowest temperature used. When Lowicryl K4M, polymerized at low temperature, is warmed up to ambient a further exothermic reaction occurs, which causes the resin temperature to rise well above ambient. Both this temperature peak and that during polymerization are reduced, but not totally eliminated, by reducing the resin volume. Air-cooled systems are inefficient compared with the low-temperature apparatus used here and the resin temperature rise is consequently greater and, even with small resin volumes, it can be very high. It is therefore unlikely for published methods that the temperature specified has been maintained in the resin during polymerization. The implications of these findings are discussed in relation to enzyme and antigen survival. Recommendations include use of very small volumes of resin, refrigerated liquid-bath rather than air-cooled systems and contact with a heat sink when specimens are warmed up to ambient temperature. Examples of enzyme reaction, antigen survival and structural preservation obtained with the method are presented.

MeSH Terms
Acrylates Freezing Histocytochemistry/methods Histological Techniques Methacrylates Plant Cells Plants/enzymology,ultrastructure Resins, Plant alpha-Amylases/metabolism
Chemicals
Acrylates Methacrylates Resins, Plant hydroxyethyl methacrylate alpha-Amylases
Authors & Affiliations
5 authors, click to expand affiliations / ORCID
Ashford A E
Allaway W G
Gubler F
Lennon A
Sleegers J
Article Info
Journal
Journal of microscopy
Abbr.
J Microsc
ISSN
0022-2720
Published
1986-11-00
Pages
107-26
Language
English
Region
England
NLM ID
0204522
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]