Home LiteratureArticle Details
PMID: 35781379 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't

Patient-specific computational haemodynamics associated with the surgical creation of an arteriovenous fistula.

Medical engineering & physics ·Vol. 105 ·2022-00-00 ·页码 103814

Hyde-Linaker G, Barrientos PH, Stoumpos S, Kingsmore DB, Kazakidi A

Abstract

Despite arteriovenous fistulae (AVF) being the preferred vascular access for haemodialysis, high primary failure rates (30-70%) and low one-year patency rates (40-70%) hamper their use. Furthermore, AVF creation has been associated with haemodynamic changes causing maladaptive cardiac remodelling leading to cardiovascular (CV) complications. In this study, we present a new workflow for characterising the haemodynamic profile prior to and following surgical creation of a successful left radiocephalic AVF in a 20-year-old end-stage kidney disease patient. The reconstructed vasculature was generated using multiple ferumoxytol-enhanced magnetic resonance angiography (FeMRA) datasets. Computational fluid dynamics (CFD) simulations utilising a scale-resolving turbulence model were completed to investigate the changes in the proximal haemodynamics following AVF creation, in addition to the post-AVF juxta-anastomosis flow patterns, which is impractical to obtain in-vivo. Following AVF creation, a significant 2-3-fold increase in blood flow rate was induced downstream of the left subclavian artery. This was validated through comparison with post-AVF patient-specific phase-contrast data. Proximal to the anastomosis, the increased flow rate yielded an increase in time-averaged wall shear stress (WSS), which is a key marker of adaptive vascular remodelling. In the juxta-anastomosis region, the success of the AVF was discussed with respect to the National Kidney Foundation's vascular access guidelines, where the patient-specific AVF met the flow rate and geometry criterion. The AVF venous diameter exceeded 6mm and the venous flow rate surpassed 600mL/min. This workflow may potentially be significant clinically when applied to multi-patient cohorts, with population-wide patient-specific conclusions being ascertained for the haemodynamic assessment of AVFs and improved surgical planning.

Keywords
Arteriovenous fistulae Chronic kidney disease Computational fluid dynamics Haemodynamics Vascular access
MeSH 主题词
Adult Arteriovenous Fistula/surgery Humans Kidney Renal Dialysis Subclavian Artery Veins Young Adult
作者与单位
共 5 位作者,点击展开单位 / ORCID
Hyde-Linaker George
Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK.
Barrientos Pauline Hall
Image Centre of Excellence, Queen Elizabeth University Hospital, Glasgow, UK.
Stoumpos Sokratis
Renal and Transplant Unit, Queen Elizabeth University Hospital, Glasgow, UK; Institute of Cardiovascular and Medical Sciences, BHF Glasgow Cardiovascular Research Centre, University of Glasgow, Glasgow G12 8TA, UK.
Kingsmore David Brian
Renal and Transplant Unit, Queen Elizabeth University Hospital, Glasgow, UK.
Kazakidi Asimina
Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK. Electronic address: [email protected].
Article Info
Journal
Medical engineering & physics
Abbr.
Med Eng Phys
ISSN
1873-4030
Corresponding email
Published
2022-00-00
电子出版
2022-00-06
页码
103814
Language
English
Country/Region
England
NLM ID
9422753
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]