Home LiteratureArticle Details
PMID: 35811698 Published · epublish English Journal Article

Assessing the Hemodynamic Impact of Anterior Leaflet Laceration in Transcatheter Mitral Valve Replacement: An in silico Study.

Frontiers in cardiovascular medicine ·Vol. 9 ·2022-00-00 ·页码 869259

Kohli K, Wei ZA, Sadri V, Siefert AW, Blanke P, Perdoncin E, Greenbaum AB, Khan JM, Lederman RJ, Babaliaros VC, Yoganathan AP, Oshinski JN

Abstract

A clinical study comparing the hemodynamic outcomes of transcatheter mitral valve replacement (TMVR) with vs. without Laceration of the Anterior Mitral leaflet to Prevent Outflow Obstruction (LAMPOON) has never been designed nor conducted. To quantify the hemodynamic impact of LAMPOON in TMVR using patient-specific computational (in silico) models. Eight subjects from the LAMPOON investigational device exemption trial were included who had acceptable computed tomography (CT) data for analysis. All subjects were anticipated to be at prohibitive risk of left ventricular outflow tract (LVOT) obstruction from TMVR, and underwent successful LAMPOON immediately followed by TMVR. Using post-procedure CT scans, two 3D anatomical models were created for each subject: (1) TMVR with LAMPOON (performed procedure), and (2) TMVR without LAMPOON (virtual control). A validated computational fluid dynamics (CFD) paradigm was then used to simulate the hemodynamic outcomes for each condition. LAMPOON exposed on average 2 ± 0.6 transcatheter valve cells (70 ± 20 mm2 total increase in outflow area) which provided an additional pathway for flow into the LVOT. As compared to TMVR without LAMPOON, TMVR with LAMPOON resulted in lower peak LVOT velocity, lower peak LVOT gradient, and higher peak LVOT effective orifice area by 0.4 ± 0.3 m/s (14 ± 7% improvement, p = 0.006), 7.6 ± 10.9 mmHg (31 ± 17% improvement, p = 0.01), and 0.2 ± 0.1 cm2 (17 ± 9% improvement, p = 0.002), respectively. This was the first study to permit a quantitative, patient-specific comparison of LVOT hemodynamics following TMVR with and without LAMPOON. The LAMPOON procedure achieved a critical increment in outflow area which was effective for improving LVOT hemodynamics, particularly for subjects with a small neo-left ventricular outflow tract (neo-LVOT).

Keywords
LAMPOON computational fluid dynamics (CFD) computed tomography (CT) left ventricular outflow tract obstruction neo-LVOT personalized computational modeling transcatheter mitral valve replacement (TMVR)
作者与单位
共 12 位作者,点击展开单位 / ORCID
Kohli Keshav
Wallace H. Coulter Department of Biomedical Engineering at the Georgia Institute of Technology and Emory University, Atlanta, GA, United States.
Wei Zhenglun Alan
Wallace H. Coulter Department of Biomedical Engineering at the Georgia Institute of Technology and Emory University, Atlanta, GA, United States. | Department of Biomedical Engineering, University of Massachusetts Lowell, Lowell, MA, United States.
Sadri Vahid
Wallace H. Coulter Department of Biomedical Engineering at the Georgia Institute of Technology and Emory University, Atlanta, GA, United States.
Siefert Andrew W
Wallace H. Coulter Department of Biomedical Engineering at the Georgia Institute of Technology and Emory University, Atlanta, GA, United States.
Blanke Philipp
Department of Radiology, St. Paul's Hospital, The University of British Columbia, Vancouver, BC, Canada.
Perdoncin Emily
Structural Heart and Valve Center, Emory University Hospital, Atlanta, GA, United States.
Greenbaum Adam B
Structural Heart and Valve Center, Emory University Hospital, Atlanta, GA, United States.
Khan Jaffar M
Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, United States.
Lederman Robert J
Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, United States.
Babaliaros Vasilis C
Structural Heart and Valve Center, Emory University Hospital, Atlanta, GA, United States.
Yoganathan Ajit P
Wallace H. Coulter Department of Biomedical Engineering at the Georgia Institute of Technology and Emory University, Atlanta, GA, United States.
Oshinski John N
Wallace H. Coulter Department of Biomedical Engineering at the Georgia Institute of Technology and Emory University, Atlanta, GA, United States. | Department of Radiology and Imaging Science, Emory University School of Medicine, Atlanta, GA, United States.
Article Info
Journal
Frontiers in cardiovascular medicine
Abbr.
Front Cardiovasc Med
ISSN
2297-055X
Published
2022-00-00
电子出版
2022-00-09
页码
869259
Language
English
Country/Region
Switzerland
NLM ID
101653388
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]