Home LiteratureArticle Details
PMID: 35983493 Published · ppublish English Journal Article

Initial evaluation of 2D and 3D simulated high-speed 1000 fps vascular contrast-flow image sequences using computational fluid dynamics (CFD).

Proceedings of SPIE--the International Society for Optical Engineering ·Vol. 12036 ·2022-00-00

Shields A, Williams K, Veeturi SS, Tutino V, Ionita C, Bednarek DR, Rudin S

Abstract

Digital subtraction angiography (DSA) remains the clinical standard for detailed visualization of the neurovasculature due to its high-spatial resolution; however, detailed blood-flow quantification is impaired by its low-temporal resolution. Advances in photon-counting detector technology have led us to develop High-Speed Angiography (HSA), where x-ray images are acquired at 1000 fps for more accurate visualization and quantification of blood flow. We have implemented a physics-based optical flow method to extract such information from HSA, but validation of the angiography-derived velocity distributions is not straightforward. Computational fluid dynamics (CFD) is widely regarded as the benchmark for hemodynamic analysis, as it provides a multitude of quantitative flow parameters throughout the volume of interest. However, there are several limitations with this method related to over-simplification of boundary conditions and suboptimal meshing (spatial resolution), that make CFD simulation results an inexact criterion for validation. To overcome this issue for HSA validation, CFD was used to generate both simulated high-speed angiograms and the corresponding ground-truth 3D flow fields to better understand the relationship between the 3D volumetric-flow distribution and the 2D projected-flow distribution as is obtained with angiography, and the subsequent 2D approximation of flow velocity. Several geometries were investigated, ranging from simple pipe models to complex patient-specific aneurysms. Simulated datasets were analyzed with the optical flow algorithm, and the effects of flow divergence, quantum mottle, and intensity gradient on the calculation were evaluated. From these simulations, we can evaluate whether flow fields reconstructed from HSA are representative of significant flow patterns in the 3D vasculature.

Keywords
Computational Fluid Dynamics Hemodynamics High-Speed Angiography Interventional Radiology Photon-Counting Detectors
作者与单位
共 7 位作者,点击展开单位 / ORCID
Shields A
Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
Williams K
Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
Veeturi S S
Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
Tutino V
Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
Ionita C
Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
Bednarek D R
Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
Rudin S
Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
Article Info
Journal
Proceedings of SPIE--the International Society for Optical Engineering
Abbr.
Proc SPIE Int Soc Opt Eng
ISSN
0277-786X
Published
2022-00-00
电子出版
2022-00-04
Language
English
Country/Region
United States
NLM ID
101524122
基金资助
NIBIB NIH HHS · R01 EB030092 · United States
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]