Home LiteratureArticle Details
PMID: 36054275 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't

Noninvasive computed tomography derived fractional flow reserve simulation based on microvascular tree model reconstruction.

International journal for numerical methods in biomedical engineering ·Vol. 39 ·No. 10 ·2023-00-00 ·页码 e3643

Yu L, He W, Qin W, Wang K, Guo W, Wang S

Abstract

To establish a novel method for noninvasive computed tomography derived fractional flow reserve (CT-FFR) simulation based on microvascular tree model reconstruction and to evaluate the feasibility and diagnostic performance of the novel method in coronary artery disease compared with invasive fractional flow reserve (FFR). Twenty patients (20 vessels) who underwent coronary computed tomography angiography (CCTA) and invasive FFR were retrospectively studied. The anatomic epicardial coronary artery model was reconstructed based on CCTA image, and the microvascular tree model was simulated based on patient-specific anatomical structures and physiological principles. Numerical simulation was subsequently performed using the CFD method with full consideration of the variation of viscosity in microvascular. Two patients with the FFR value of .80 were selected for adjusting the parameters of the model, while the remaining 18 patients were selected as a validation cohort. After simulation, CT-FFR was compared with invasive FFR with a threshold of .80. Eleven (55%) patients had an abnormal FFR that was less than or equal to .80. Compared with invasive FFR, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CT-FFR with an optimal threshold of .80 were 100%, 77.8%, 81.8%, 100%, 88.89%, respectively. There were a good correlation and consistency between CT-FFR and invasive FFR. Time per patient of CT-FFR analysis was less than 15 min. CT-FFR based on microvascular tree model reconstruction is feasible with good diagnostic performance. It requires a short processing time with excellent accuracy. Large multicenter prospective studies are required for further demonstrating the diagnostic performance of this novel model in myocardium ischemia evaluation.

Keywords
coronary artery disease coronary computed tomography angiography diagnostic performance fractional flow reserve microvascular tree model myocardium ischemia noninvasive
MeSH 主题词
Humans Coronary Angiography/methods Coronary Artery Disease/diagnostic imaging Coronary Stenosis/diagnosis Fractional Flow Reserve, Myocardial/physiology Retrospective Studies Tomography, X-Ray Computed
作者与单位
共 6 位作者,点击展开单位 / ORCID
Yu Long
Department of aeronautics and astronautics, Fudan University, Shanghai, China.
He Wei
Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China.
Qin Wang
Department of aeronautics and astronautics, Fudan University, Shanghai, China.
Wang Keqiang
Institute of Panvascular Medicine, Zhongshan Hospital, Fudan University, Shanghai, China.
Guo Weifeng
Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China.
Wang Shengzhang ORCID
Department of aeronautics and astronautics, Fudan University, Shanghai, China. | Institute of Biomedical Engineering Technology, Academy for Engineering and Technology, Fudan University, Shanghai, China.
Article Info
Journal
International journal for numerical methods in biomedical engineering
Abbr.
Int J Numer Method Biomed Eng
ISSN
2040-7947
Published
2023-00-00
电子出版
2022-00-29
页码
e3643
Language
English
Country/Region
England
NLM ID
101530293
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]