Virus transport and infection evaluation in a passenger elevator with a COVID-19 patient.

Indoor air ·Vol. 32 ·No. 10 ·2022-00-00 ·页码 e13125

Du C, Chen Q

Abstract

Contaminant transport and flow distribution are very important during an elevator ride, as the reduced social distancing may increase the infection rate of airborne diseases such as COVID-19. Studying the airflow and contaminant concentration in an elevator is not straightforward because the flow pattern inside an elevator changes dramatically with passenger movement and frequent door opening. Since very little experimental data were available for elevators, this investigation validated the use of computational fluid dynamics (CFD) based on the RNG k- ∈ $$ \in $$ turbulence model to predict airflow and contaminant transport in a scaled, empty airliner cabin with a moving passenger. The movement of the passenger in the cabin created a dynamic airflow and transient contaminant dispersion that were similar to those in an elevator. The computed results agreed reasonably well with the experimental data for the cabin. The validated CFD program was then used to calculate the distributions of air velocity, air temperature, and particle concentration during an elevator ride with an index patient. The CFD results showed that the airflow pattern in the elevator was very complex due to the downward air supply from the ceiling and upward thermal plumes generated by passengers. This investigation studied different respiratory activities of the index patient, that is, breathing only, breathing, and coughing with and without a mask, and talking. The results indicated that the risk of infection was generally low because of the short duration of the elevator ride. If the index patient talked in the elevator, two passengers in the closest proximity to distance would be infected.

Keywords
CFD COVID-19 airborne diseases dynamic mesh risk assessment
MeSH 主题词
Humans Elevators and Escalators Air Pollution, Indoor COVID-19 Aircraft Hydrodynamics
作者与单位
共 2 位作者,点击展开单位 / ORCID
Du Chengbo ORCID
School of Mechanical Engineering, Purdue University, West Lafayette, Indiana, USA.
Chen Qingyan ORCID
Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong.
Article Info
Journal
Indoor air
Abbr.
Indoor Air
ISSN
1600-0668
Published
2022-00-00
页码
e13125
Language
English
Country/Region
England
NLM ID
9423515
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]