Home LiteratureArticle Details
PMID: 36336682 Published · epublish English Journal Article Research Support, Non-U.S. Gov't

Automatic segmentation of the great arteries for computational hemodynamic assessment.

Montalt-Tordera J, Pajaziti E, Jones R, Sauvage E, Puranik R, Singh AAV, Capelli C, Steeden J, Schievano S, Muthurangu V

Abstract

Computational fluid dynamics (CFD) is increasingly used for the assessment of blood flow conditions in patients with congenital heart disease (CHD). This requires patient-specific anatomy, typically obtained from segmented 3D cardiovascular magnetic resonance (CMR) images. However, segmentation is time-consuming and requires expert input. This study aims to develop and validate a machine learning (ML) method for segmentation of the aorta and pulmonary arteries for CFD studies. 90 CHD patients were retrospectively selected for this study. 3D CMR images were manually segmented to obtain ground-truth (GT) background, aorta and pulmonary artery labels. These were used to train and optimize a U-Net model, using a 70-10-10 train-validation-test split. Segmentation performance was primarily evaluated using Dice score. CFD simulations were set up from GT and ML segmentations using a semi-automatic meshing and simulation pipeline. Mean pressure and velocity fields across 99 planes along the vessel centrelines were extracted, and a mean average percentage error (MAPE) was calculated for each vessel pair (ML vs GT). A second observer (SO) segmented the test dataset for assessment of inter-observer variability. Friedman tests were used to compare ML vs GT, SO vs GT and ML vs SO metrics, and pressure/velocity field errors. The network's Dice score (ML vs GT) was 0.945 (interquartile range: 0.929-0.955) for the aorta and 0.885 (0.851-0.899) for the pulmonary arteries. Differences with the inter-observer Dice score (SO vs GT) and ML vs SO Dice scores were not statistically significant for either aorta or pulmonary arteries (p = 0.741, p = 0.061). The ML vs GT MAPEs for pressure and velocity in the aorta were 10.1% (8.5-15.7%) and 4.1% (3.1-6.9%), respectively, and for the pulmonary arteries 14.6% (11.5-23.2%) and 6.3% (4.3-7.9%), respectively. Inter-observer (SO vs GT) and ML vs SO pressure and velocity MAPEs were of a similar magnitude to ML vs GT (p > 0.2). ML can successfully segment the great vessels for CFD, with errors similar to inter-observer variability. This fast, automatic method reduces the time and effort needed for CFD analysis, making it more attractive for routine clinical use.

Keywords
Computational fluid dynamics Congenital heart disease Machine learning Magnetic resonance imaging Neural network Segmentation
MeSH 主题词
Humans Retrospective Studies Predictive Value of Tests Hemodynamics Magnetic Resonance Imaging Aorta/diagnostic imaging
作者与单位
共 10 位作者,点击展开单位 / ORCID
Montalt-Tordera Javier
UCL Institute of Cardiovascular Science, UCL, London, UK.
Pajaziti Endrit
UCL Institute of Cardiovascular Science, UCL, London, UK.
Jones Rod
Great Ormond Street Hospital, London, UK.
Sauvage Emilie
UCL Institute of Cardiovascular Science, UCL, London, UK.
Puranik Rajesh
Children's Hospital at Westmead, Sydney, Australia. | Faculty of Medicine and Health, University of Sydney, Sydney, Australia.
Singh Aakansha Ajay Vir
Children's Hospital at Westmead, Sydney, Australia. | Faculty of Medicine and Health, University of Sydney, Sydney, Australia.
Capelli Claudio
UCL Institute of Cardiovascular Science, UCL, London, UK.
Steeden Jennifer
UCL Institute of Cardiovascular Science, UCL, London, UK.
Schievano Silvia
UCL Institute of Cardiovascular Science, UCL, London, UK.
Muthurangu Vivek ORCID
UCL Institute of Cardiovascular Science, UCL, London, UK. [email protected].
Article Info
Journal
Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
Abbr.
J Cardiovasc Magn Reson
ISSN
1532-429X
Corresponding email
Published
2022-00-07
电子出版
2022-00-07
页码
57
Language
English
Country/Region
England
NLM ID
9815616
基金资助
Medical Research Council · MR/S032290/1 · United Kingdom
British Heart Foundation · PG/17/6/32797 · United Kingdom
British Heart Foundation · NH/18/1/33511 · United Kingdom
European Research Council · ERC-2017-StG-757923 · International
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]