Home LiteratureArticle Details
PMID: 36403271 Published · ppublish English

Multimodality imaging results of TAP versus novel modified TAP stenting in coronary bifurcation: From bench testing to first-in-man investigation.

Ng JCK, Ang H, Zhong L, Hakim D, Marmagkiolis K, Foin N, Leesar MA

Abstract

We investigated the results of T and small protrusion (TAP) versus a novel modification of TAP (mTAP) stenting by multimodality imaging in bench testing and in patients with coronary bifurcation lesions (CBL). TAP stenting is a suboptimal technique for bailout side branch (SB) stenting. In a bench model, optical coherence tomography (OCT), microscopic examinations (ME), and computational fluid dynamics (CFD) were performed after TAP and mTAP stenting. In 20 patients with CBL, 80 intravascular ultrasound (IVUS) examinations were performed during mTAP stenting in which the SB stent was pulled-back to indent the inflated main vessel (MV) balloon and deployed while deflating it. For TAP stenting, the tip of the SB stent was positioned in the MV and deployed. In bench testing, OCT showed neocarina length (NL) was shorter and minimum stent area (MSA) was larger after mTAP versus TAP stenting (2.84 ± 0.70 vs. 4.80 ± 020 mm; 6.75 ± 1.50 vs. 4.5 ± 2.2 mm2 ; respectively; p < 0.05). By ME, NL was shorter and shear rate trended lower after mTAP versus TAP stenting. In patients, IVUS showed MSA was larger after versus before mTAP stenting (6.32 ± 0.58 vs. 5.21 ± 0.56 mm2 ; p < 0.01); NL was 1.43 ± 0.22 mm with SB ostium coverage. The Seattle Angina questionnaire (SAQ) score was higher at 6 months versus baseline (85 ± 4.0 vs. 48 ± 6.0, respectively; p < 0.001). This multimodality imaging study showed, for the first time, mTAP stenting resulted in larger stent area and shorter neocarina than TAP stenting in bench testing. In patients with CBL, mTAP stenting led to larger stent area, short neocarina with complete SB ostium coverage, and improved the SAQ score at follow-up.

Keywords
IVUS OCT bifurcation lesions mTAP stenting: TAP stenting
MeSH 主题词
Humans Coronary Artery Disease/diagnostic imaging,therapy Angioplasty, Balloon, Coronary/methods Coronary Angiography Treatment Outcome Stents Coronary Vessels/diagnostic imaging
Article Info
Journal
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Abbr.
Catheter Cardiovasc Interv
ISSN
1522-726X
Published
2023-00-00
Language
English
Country/Region
United States
NLM ID
100884139
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]