Home LiteratureArticle Details
PMID: 36474904 Published · epublish English Journal Article

Analysis of the Optimum Tapering Angle in Microanastomosis Using Computational Fluid Dynamics.

Yonago acta medica ·Vol. 65 ·No. 4 ·2022-11-00 ·页码 296-302

Yagi S, Ikuta K, Miyazaki S, Umeda R, Kanayama H, Hifny MA, Morita M, Nakagaki M, Tanabe M, Suyama Y, Fukuoka K

Abstract

In free flap transfer, size discrepancy between the vascular pedicle and recipient vessel can create a problem for microsurgeons and sometimes induces postoperative thrombus formation. When there is a major difference between the diameters of the vascular pedicle and the recipient vessel, the larger vessel is often tapered to perform the anastomosis properly. However, the decision on the tapering angle used depends mostly on the operator's experience. In this study, computational fluid dynamics (CFD) was used to investigate the optimum tapering angle. Using ANSYS ICEM 16.0 (ANSYS Japan, Tokyo, Japan), simulated vessels of diameters 1.5 mm and 3.0 mm were designed and then used to produce four anastomosis models with the 3.0-mm vessel tapered at angles of 15º, 30º, 60º, and 90º (no tapering). Venous perfusion with a mean value of 13.0 mL/min was simulated, and this was passed through the four anastomosis models in both the forward direction (F), from the smaller to the larger vessel, and the retrograde direction (R), from the larger to the smaller vessel. The velocity, wall shear stress (WSS), and oscillatory shear index (OSI) were measured in these eight patterns and then analyzed using OpenFOAM version 5. The decrease in velocity was limiting. The WSS was greater in the R direction than the F direction at every tapering angle. The OSI also tended to be almost the same in the F direction, and lower at smaller tapering angles in the R direction. And, it was greater in the F direction than in the R direction at every tapering angle. The OSI values for 15º and 30º were almost identical in the R direction. The risk of thrombus formation is thought to be lower when tapering is used for anastomosis if the direction of flow is from the larger to the smaller vessel, rather than vice versa. These results also suggest that the optimum tapering angle is approximately 30º in both directions.

Keywords
computational fluid dynamics microsurgery simulation size discrepancy tapering
作者与单位
共 11 位作者,点击展开单位 / ORCID
Yagi Shunjiro
Department of Plastic and Reconstructive Surgery, Tottori University Hospital, Yonago 683-8504, Japan.
Ikuta Kento
Department of Plastic and Reconstructive Surgery, Tottori University Hospital, Yonago 683-8504, Japan.
Miyazaki Shohei
Cardio Flow Design, Inc., Chiyoda 102-0082, Tokyo, Japan.
Umeda Ryunosuke
Department of Plastic and Reconstructive Surgery, Tottori University Hospital, Yonago 683-8504, Japan.
Kanayama Haruka
Department of Plastic and Reconstructive Surgery, Tottori University Hospital, Yonago 683-8504, Japan.
Hifny Mahmoud A
Department of Plastic Surgery, Qena University Hospital, South Valley University, Qena, Egypt.
Morita Maki
Department of Plastic and Reconstructive Surgery, Tottori University Hospital, Yonago 683-8504, Japan.
Nakagaki Makoto
Department of Plastic and Reconstructive Surgery, Tottori University Hospital, Yonago 683-8504, Japan.
Tanabe Makoto
Department of Plastic and Reconstructive Surgery, Tottori University Hospital, Yonago 683-8504, Japan.
Suyama Yoshiko
Department of Plastic and Reconstructive Surgery, Tottori University Hospital, Yonago 683-8504, Japan.
Fukuoka Kohei
Department of Plastic and Reconstructive Surgery, Tottori University Hospital, Yonago 683-8504, Japan.
Article Info
Journal
Yonago acta medica
Abbr.
Yonago Acta Med
ISSN
0513-5710
Published
2022-11-00
电子出版
2022-00-28
页码
296-302
Language
English
Country/Region
Japan
NLM ID
0414002
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]