Home LiteratureArticle Details
PMID: 36517696 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't

Aneurysm Neck Overestimation has a Relatively Modest Impact on Simulated Hemodynamics.

Cardiovascular engineering and technology ·Vol. 14 ·No. 2 ·2023-00-00 ·页码 252-263

MacDonald DE, Cancelliere NM, Pereira VM, Steinman DA

Abstract

Overestimation of intracranial aneurysm neck width by 3D angiography is a recognized clinical problem, and has long been a concern for image-based computational fluid dynamics (CFD). Recently, it was demonstrated that neck overestimation in 3D rotational angiography (3DRA) could be corrected via segmentation with upsampled resolution and gradient enhancement (SURGE). Our aim was to leverage this approach to determine whether and how neck overestimation actually impacts CFD-derived hemodynamics. A subset of 17 cases having the largest neck errors from a consecutive clinical sample of 60 was segmented from 3DRA using both standard watershed and SURGE methods. High-fidelity, pulsatile CFD was performed, and a variety of scalar hemodynamic parameters that have been associated with aneurysm growth and/or rupture status were derived. With a few exceptions, flow and wall shear stress (WSS) patterns were qualitatively similar between neck-overestimated and corrected models. Sac-averaged WSS values were significantly lower after neck correction (p = 0.0005) but were highly correlated with their neck-overestimated counterparts (R2 = 0.98). Jet impingement was significantly more concentrated in the neck-corrected vs. -uncorrected models (p = 0.0011), and only moderately correlated (R2 = 0.61). Parameters quantifying velocity or WSS fluctuations were not significantly different after neck correction, but this reflected their poorer correlations (R2 < 0.4). Nevertheless, for all hemodynamic parameters, median absolute differences were < 26%, and no parameter had more than 5/17 cases with absolute differences > 50%. Differences in hemodynamics due to neck width overestimation were found to be at most equal to, and often less than, those reported for other sources of error/uncertainty in intracranial aneurysm CFD, such as solver settings or assumed inflow rates.

Keywords
Aneurysm CFD Flow instability Hemodynamics Segmentation
MeSH 主题词
Humans Intracranial Aneurysm/diagnostic imaging Imaging, Three-Dimensional Hemodynamics Stress, Mechanical Hydrodynamics
作者与单位
共 4 位作者,点击展开单位 / ORCID
MacDonald Daniel E
Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Rd, Toronto, ON, M5S 3G8, Canada.
Cancelliere Nicole M
RADIS Lab, Li Ka-Shing Knowledge Institute, St. Michael's Hospital, University of Toronto, Toronto, ON, Canada.
Pereira Vitor M
RADIS Lab, Li Ka-Shing Knowledge Institute, St. Michael's Hospital, University of Toronto, Toronto, ON, Canada. | Division of Neurosurgery, Department of Surgery, St. Michael's Hospital, University of Toronto, Toronto, ON, Canada.
Steinman David A ORCID
Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Rd, Toronto, ON, M5S 3G8, Canada. [email protected].
Article Info
Journal
Cardiovascular engineering and technology
Abbr.
Cardiovasc Eng Technol
ISSN
1869-4098
Corresponding email
Published
2023-00-00
电子出版
2022-00-14
页码
252-263
Language
English
Country/Region
United States
NLM ID
101531846
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]