Home LiteratureArticle Details
PMID: 36739299 Published · epublish English Journal Article

Measurements and computational fluid dynamics investigation of the indoor radon distribution in a typical naturally ventilated room.

Scientific reports ·Vol. 13 ·No. 1 ·2023-02-04 ·页码 2064

Adelikhah M, Imani M, Kovács T

Abstract

Based on the European Union Basic Safety Standards to protect people against exposure to ionizing radiation, establishing and addressing the reference levels for indoor radon concentrations is necessary. Therefore, the indoor radon concentration should be monitored and control in dwelling and workplaces. However, proper ventilation and sustainability are the major factors that influence how healthy the environment in a building is for its occupants. In this paper, the indoor radon distribution in a typical naturally ventilated room under two scenarios (when the door is closed and open) using the computational fluid dynamics (CFD) technique was studied. The CFD code ANSYS Fluent 2020 R1 based on the finite volume method was employed before the simulation results were compared with analytical calculations as well as passive and active measurements. The average radon concentration from the CFD simulation was found to be between 70.21 and 66.25 Bq m-3 under closed and open-door conditions, respectively, at the desired ventilation rate of 1 ACH (Air Changes per Hour). Moreover, the highest concentrations of radon were measured close to the floor and the lowest values were recorded near to the inlet, resulting in the airflow velocity profile. The simulation results were in good agreement with the maxima of 19% and 7% compared to analytical calculations at different indoor air velocities in the open- and closed-door scenarios, respectively. The measured radon concentrations obtained by the active measurements also fitted well with the CFD results, for example, with a relative standard deviation of around 7% and 2% when measured by AlphaGUARD and RAD7 monitors at a height of 1.0 m above the ground in the open-door scenario. From the simulation results, the effective dose received by an individual from the indoor air of the workplace was also calculated.

作者与单位
共 3 位作者,点击展开单位 / ORCID
Adelikhah Mohammademad
Institute of Radiochemistry and Radioecology, University of Pannonia, Veszprém, 8200, Hungary.
Imani Morteza
Engineering Department, G.C, Shahid Beheshti University, P.O. Box: 1983963113, Tehran, Iran.
Kovács Tibor
Institute of Radiochemistry and Radioecology, University of Pannonia, Veszprém, 8200, Hungary. [email protected].
Article Info
Journal
Scientific reports
Abbr.
Sci Rep
ISSN
2045-2322
Corresponding email
Published
2023-02-04
电子出版
2023-00-04
页码
2064
Language
English
Country/Region
England
NLM ID
101563288
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]