Home LiteratureArticle Details
PMID: 36925522 Published · epublish English Journal Article

Research on the cross-contamination in the confined conference room with the radiant floor heating system integrated with the down-supply ventilation.

Heliyon ·Vol. 9 ·No. 3 ·2023-03-00 ·页码 e14389

Wu J, Xu L, Shen J

Abstract

The performance of a confined conference room under radiant heat floor combined with down-supply ventilation (RFDS) is investigated. The purpose of the study is to reveal the mechanism of indoor contaminants transmission from infected person and to protect the occupants. The exhaled contaminant dispersion was simulated using a CFD model and experimentally validated in an office with the down-supply ventilation (DS). The effects of radiant floor (RF) combined with down-supply ventilation on airflow and contaminant distribution in the room was evaluated with regard to different RF temperatures and inlet velocities. The influence of downdraft from the envelope on the airflow pattern of the room is also discussed. It is proved that the exposure risk of pollutants can be reduced by strengthening the insulation of the envelope. The simulation results showed that the proposed RFDS system could significantly reduce the level of exposure to contaminants in the breathing zone (BZ) of occupants. In this research case, the RFDS reduced the average exposure rates by more than 50% relative to the case with the only down-supply warm air heating. Furthermore, With improved envelope insulation, the probability of infection can be reduced by more than 80% only by avoiding a simultaneous inlet velocity of 0.3 m/s at RF temperatures no less than 27 °C. The results suggested an improved fresh air heating mode for passive ultra-low energy consumption buildings with good thermal insulation and air tightness.

Keywords
Cross-contamination Down-supply ventilation Envelope insulation Radiant floor system
作者与单位
共 3 位作者,点击展开单位 / ORCID
Wu Jie
School of Architecture, Soochow University, Suzhou, China.
Xu Liang
School of Architecture, Soochow University, Suzhou, China.
Shen JingHua
School of Architecture, Soochow University, Suzhou, China.
Article Info
Journal
Heliyon
Abbr.
Heliyon
ISSN
2405-8440
Published
2023-03-00
电子出版
2023-00-09
页码
e14389
Language
English
Country/Region
England
NLM ID
101672560
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]