Hemodynamic investigation of a novel rotary displacement blood pump for extracorporeal membrane oxygenation.

International journal for numerical methods in biomedical engineering ·Vol. 39 ·No. 6 ·2023-00-00 ·页码 e3705

Xue Q, Ren X, Gao B, Li S, Song Z, Ding J, Chang Y

Abstract

Extracorporeal membrane oxygenation (ECMO) is a life support system used in the treatment of severe respiratory and circulatory failure. High shear stress caused by the high rotational speed of centrifugal blood pumps can cause hemolysis and platelet activation, which are among the major factors leading to the complications of the ECMO system. In this study, a novel blood pump named rotary displacement blood pump (RDBP), which can considerably reduce rotational speed and shear stress while ensuring the normal pressure flow relationship, was proposed. We employed computational fluid dynamics (CFD) analysis to investigate the performance of RDBP under adult ECMO support operating conditions (5 L/min with 350 mmHg). The efficiency and H-Q curves of the RDBP were calculated to evaluate its hydraulic performance, and pressure, flow patterns, and shear stress distribution were analyzed to estimate the hemodynamic characteristics in the pump. In addition, the modified index of hemolysis (MIH) was calculated for the RDBP based on a Eulerian approach. The hydraulic efficiency of the RDBP was 47.28%. The velocity distribution of flow field in the pump was relatively uniform. Most of the liquid (more than 75%) in the pump was exposed to low scale shear stress (<1 Pa), which was close to normal physiological conditions. The gap area was the main distribution location of high scale shear stress. The high wall shear stress (>9 Pa) volume fraction of the RDBP was small and located in the boundary areas between the rotor's edge and the housing. The MIH value of the RDBP was 9.87 ± 0.93 (mean ± SD). The RDBP can achieve better hydraulic efficiency and hemodynamic performance at lower rotational speed. The design of this novel pump is expected to provide a new direction for developing a blood pump for ECMO.

Keywords
CFD ECMO blood pump hemodynamics rotary displacement blood pump
MeSH 主题词
Humans Extracorporeal Membrane Oxygenation Equipment Design Hemolysis Hemodynamics/physiology Heart-Assist Devices
作者与单位
共 7 位作者,点击展开单位 / ORCID
Xue Qingxin
Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China.
Ren Xiaoyu
Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China.
Gao Bin ORCID
Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China.
Li Shu
National Institutes for Food and Drug Control, Institute for Medical Device Control, Beijing, China.
Song Zhiming
Department of Cardiac Surgery, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China.
Ding Jinli
Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Chang Yu
National Clinical Research Center for Child Health, The Children's Hospital Zhejiang University School of Medicine, Hangzhou, China.
Article Info
Journal
International journal for numerical methods in biomedical engineering
Abbr.
Int J Numer Method Biomed Eng
ISSN
2040-7947
Published
2023-00-00
电子出版
2023-00-02
页码
e3705
Language
English
Country/Region
England
NLM ID
101530293
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]