Home LiteratureArticle Details
PMID: 37221220 Published · epublish English Journal Article

In-silico investigations of haemodynamic parameters for a blunt thoracic aortic injury case.

Scientific reports ·Vol. 13 ·No. 1 ·2023-00-23 ·页码 8355

Dadras R, Jabbari A, Asl NK, Soltani M, Rafiee F, Parsaee M, Golchin S, Pouraliakbar H, Sadeghipour P, Alimohammadi M

Abstract

Accounting for 1.5% of thoracic trauma, blunt thoracic aortic injury (BTAI) is a rare disease with a high mortality rate that nowadays is treated mostly via thoracic endovascular aortic repair (TEVAR). Personalised computational models based on fluid-solid interaction (FSI) principals not only support clinical researchers in studying virtual therapy response, but also are capable of predicting eventual outcomes. The present work studies the variation of key haemodynamic parameters in a clinical case of BTAI after successful TEVAR, using a two-way FSI model. The three-dimensional (3D) patient-specific geometries of the patient were coupled with three-element Windkessel model for both prior and post intervention cases, forcing a correct prediction of blood flow over each section. Results showed significant improvement in velocity and pressure distribution after stenting. High oscillatory, low magnitude shear (HOLMES) regions require careful examination in future follow-ups, since thrombus formation was confirmed in some previously clinically reported cases of BTAI treated with TEVAR. The strength of swirling flows along aorta was also damped after stent deployment. Highlighting the importance of haemodynamic parameters in case-specific therapies. In future studies, compromising motion of aortic wall due to excessive cost of FSI simulations can be considered and should be based on the objectives of studies to achieve a more clinical-friendly patient-specific CFD model.

MeSH 主题词
Humans Hemodynamics Alarmins Aorta Endovascular Aneurysm Repair Motion
化学物质
Alarmins
作者与单位
共 10 位作者,点击展开单位 / ORCID
Dadras Rezvan
Department of Mechanical Engineering, K. N. Toosi Univeristy of Technology, Tehran, Iran.
Jabbari Alireza
Department of Mechanical Engineering, K. N. Toosi Univeristy of Technology, Tehran, Iran.
Asl Narges Kamaei
Department of Mechanical Engineering, K. N. Toosi Univeristy of Technology, Tehran, Iran.
Soltani Madjid
Department of Mechanical Engineering, K. N. Toosi Univeristy of Technology, Tehran, Iran.
Rafiee Farnaz
Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, Iran.
Parsaee Mozhgan
Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, Iran.
Golchin Shadi
Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, Iran.
Pouraliakbar Hamidreza
Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, Iran.
Sadeghipour Parham
Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, Iran. [email protected].
Alimohammadi Mona
Department of Mechanical Engineering, K. N. Toosi Univeristy of Technology, Tehran, Iran. [email protected].
Article Info
Journal
Scientific reports
Abbr.
Sci Rep
ISSN
2045-2322
Published
2023-00-23
电子出版
2023-00-23
页码
8355
Language
English
Country/Region
England
NLM ID
101563288
勘误 / 撤稿关联
ErratumIn
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]