Calibration of patient-specific boundary conditions for coupled CFD models of the aorta derived from 4D Flow-MRI.

Frontiers in bioengineering and biotechnology ·Vol. 11 ·2023-00-00 ·页码 1178483

Black SM, Maclean C, Hall Barrientos P, Ritos K, McQueen A, Kazakidi A

Abstract

Introduction: Patient-specific computational fluid dynamics (CFD) models permit analysis of complex intra-aortic hemodynamics in patients with aortic dissection (AD), where vessel morphology and disease severity are highly individualized. The simulated blood flow regime within these models is sensitive to the prescribed boundary conditions (BCs), so accurate BC selection is fundamental to achieve clinically relevant results. Methods: This study presents a novel reduced-order computational framework for the iterative flow-based calibration of 3-Element Windkessel Model (3EWM) parameters to generate patient-specific BCs. These parameters were calibrated using time-resolved flow information derived from retrospective four-dimensional flow magnetic resonance imaging (4D Flow-MRI). For a healthy and dissected case, blood flow was then investigated numerically in a fully coupled zero dimensional-three dimensional (0D-3D) numerical framework, where the vessel geometries were reconstructed from medical images. Calibration of the 3EWM parameters was automated and required ~3.5 min per branch. Results: With prescription of the calibrated BCs, the computed near-wall hemodynamics (time-averaged wall shear stress, oscillatory shear index) and perfusion distribution were consistent with clinical measurements and previous literature, yielding physiologically relevant results. BC calibration was particularly important in the AD case, where the complex flow regime was captured only after BC calibration. Discussion: This calibration methodology can therefore be applied in clinical cases where branch flow rates are known, for example, via 4D Flow-MRI or ultrasound, to generate patient-specific BCs for CFD models. It is then possible to elucidate, on a case-by-case basis, the highly individualized hemodynamics which occur due to geometric variations in aortic pathology high spatiotemporal resolution through CFD.

Keywords
4D Flow-MRI CFD Windkessel aortic dissection boundary conditions calibration patient-specific
作者与单位
共 6 位作者,点击展开单位 / ORCID
Black Scott MacDonald
Department of Biomedical Engineering, University of Strathclyde, Glasgow, United Kingdom.
Maclean Craig
Research and Development, Terumo Aortic, Glasgow, United Kingdom.
Hall Barrientos Pauline
Clinical Physics, Queen Elizabeth University Hospital, NHS Greater Glasgow and Clyde, Glasgow, United Kingdom.
Ritos Konstantinos
Department of Mechanical and Aerospace Engineering, University of Strathclyde, Glasgow, United Kingdom. | Department of Mechanical Engineering, University of Thessaly, Volos, Greece.
McQueen Alistair
Department of Biomedical Engineering, University of Glasgow, Glasgow, United Kingdom.
Kazakidi Asimina
Department of Biomedical Engineering, University of Strathclyde, Glasgow, United Kingdom.
Article Info
Journal
Frontiers in bioengineering and biotechnology
Abbr.
Front Bioeng Biotechnol
ISSN
2296-4185
Published
2023-00-00
电子出版
2023-00-11
页码
1178483
Language
English
Country/Region
Switzerland
NLM ID
101632513
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]