Home LiteratureArticle Details
PMID: 37370619 Published · epublish English Journal Article

CFD Study of the Effect of the Angle Pattern on Iliac Vein Compression Syndrome.

Bioengineering (Basel, Switzerland) ·Vol. 10 ·No. 6 ·2023-06-05

Chen HW, Chen CH, Fan YJ, Lin CY, Hsu WH, Su IC, Lin CL, Chiang YC, Huang HM

Abstract

Iliac vein compression syndrome (IVCS, or May-Thurner syndrome) occurs due to the compression of the left common iliac vein between the lumbar spine and right common iliac artery. Because most patients with compression are asymptomatic, the syndrome is difficult to diagnose based on the degree of anatomical compression. In this study, we investigated how the tilt angle of the left common iliac vein affects the flow patterns in the compressed blood vessel using three-dimensional computational fluid dynamic (CFD) simulations to determine the flow fields generated after compression sites. A patient-specific iliac venous CFD model was created to verify the boundary conditions and hemodynamic parameter set in this study. Thirty-one patient-specific CFD models with various iliac venous angles were developed using computed tomography (CT) angiograms. The angles between the right or left common iliac vein and inferior vena cava at the confluence level of the common iliac vein were defined as α1 and α2. Flow fields and vortex locations after compression were calculated and compared according to the tilt angle of the veins. Our results showed that α2 affected the incidence of flow field disturbance. At α2 angles greater than 60 degrees, the incidence rate of blood flow disturbance was 90%. In addition, when α2 and α1 + α2 angles were used as indicators, significant differences in tilt angle were found between veins with laminar, transitional, and turbulent flow (p < 0.05). Using this mathematical simulation, we concluded that the tilt angle of the left common iliac vein can be used as an auxiliary indicator to determine IVCS and its severity, and as a reference for clinical decision making.

Keywords
IVCS angle pattern computational fluid dynamics finite element iliac vein
作者与单位
共 9 位作者,点击展开单位 / ORCID
Chen Hsuan-Wei
Graduate Institute of Biomedical Materials and Tissue Engineering, Taipei Medical University, Taipei 11031, Taiwan.
Chen Chao-Hsiang
Department of Imaging Medicine, Taipei Medical University Hospital, Taipei 11031, Taiwan.
Fan Yu-Jui
School of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan.
Lin Chun-Yu
Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taipei 114202, Taiwan.
Hsu Wen-Hsien
Department of Lymphovascular Surgery, Taipei Municipal Wanfang Hospital, Taipei 11600, Taiwan.
Su I-Chang
Department of Surgery, School of Medicine, College of Medicine, Taipei Medical University, Taipei 11031, Taiwan. | Department of Neurosurgery, Taipei Medical University-Shuang Ho Hospital, Ministry of Health and Welfare, New Taipei City 235041, Taiwan.
Lin Chun-Li ORCID
Medical Device Innovation and Translation Center, Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 112304, Taiwan.
Chiang Yuan-Ching
Department of Mechanical Engineering, Chinese Culture University, Taipei 111396, Taiwan.
Huang Haw-Ming ORCID
School of Dentistry, Taipei Medical University, Taipei 11031, Taiwan.
Article Info
Journal
Bioengineering (Basel, Switzerland)
Abbr.
Bioengineering (Basel)
ISSN
2306-5354
Published
2023-06-05
电子出版
2023-00-05
Language
English
Country/Region
Switzerland
NLM ID
101676056
基金资助
Taipei Medical University Hospital · 111TMU-TMUH-16
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]