Do the stent blind insertion into the main portal vein (MPV) and stent diameter influence the surgical outcome of the transjugular intrahepatic portosystemic shunt (TIPS)?

Computers in biology and medicine ·Vol. 164 ·2023-00-00 ·页码 107306

Jiang L, Han H, Yang J, Fang R, Xin Y, Chen Q, Yao J, Li Z

Abstract

Transjugular intrahepatic portosystemic shunt (TIPS) surgery is a clinical intervention to treat portal hypertension (PH) by deploying a covered stent to establish a shunt path for the portal vein (PV) system, and proper surgical strategy is of great importance to balance the shunt effect and the risk of complications. To understand the clinical strategies of the stent blind insertion and stent selection in clinic, this study investigated the effects of varying stent insertion positions and diameters on the PV hemodynamics and the shunt effect by computational fluid dynamics (CFD) analysis of five post-TIPS subjects. The results showed that the successful TIPS surgeries of the five PH subjects were confirmed by quantifying their pressure drops. The stent insertion positions at the main portal vein (MPV) slightly affected the clinically concerned hemodynamic indexes (i.e., MPV pressure, stent-outlet velocity) and the shunt index (SI). This indicated that the position of the stent going into the MPV may not need to be deliberately selected. Moreover, the covered stents with 6 mm and 8 mm diameters slightly influenced the hemodynamics as well, but the large-diameter stent better improved the shunt effect compared to the small-diameter one. Despite this, the 6 mm stent was suggested thanks to the higher risk of the hepatic encephalopathy (HE) observed in clinic, which indicated the excessive shunt of the 8 mm stent. The current work revealed the effects of different TIPS strategies on the surgical outcome, and could be useful for potential clinical practices.

Keywords
Blind insertion Computational fluid dynamics Portal hypertension Stent diameter Transjugular intrahepatic portosystemic shunt
MeSH 主题词
Humans Portal Vein/surgery Portasystemic Shunt, Transjugular Intrahepatic/adverse effects,methods Hypertension, Portal/surgery Stents/adverse effects Treatment Outcome
作者与单位
共 8 位作者,点击展开单位 / ORCID
Jiang Lingyu
Biomechanics Laboratory, School of Biological Science & Medical Engineering, Southeast University, Nanjing, 210096, China.
Han Hao
Department of Ultrasound Medicine, Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing, 210008, Jiangsu, People's Republic of China; Medical Imaging Center, Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing, 210008, Jiangsu, People's Republic of China.
Yang Jian
Department of Ultrasound Medicine, Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing, 210008, Jiangsu, People's Republic of China; Medical Imaging Center, Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing, 210008, Jiangsu, People's Republic of China.
Fang Runxin
Biomechanics Laboratory, School of Biological Science & Medical Engineering, Southeast University, Nanjing, 210096, China.
Xin Ying
Department of Ultrasound Medicine, Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing, 210008, Jiangsu, People's Republic of China; Medical Imaging Center, Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing, 210008, Jiangsu, People's Republic of China.
Chen Qiang
Biomechanics Laboratory, School of Biological Science & Medical Engineering, Southeast University, Nanjing, 210096, China. Electronic address: [email protected].
Yao Jing
Department of Ultrasound Medicine, Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing, 210008, Jiangsu, People's Republic of China; Medical Imaging Center, Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing, 210008, Jiangsu, People's Republic of China. Electronic address: [email protected].
Li Zhiyong
Biomechanics Laboratory, School of Biological Science & Medical Engineering, Southeast University, Nanjing, 210096, China; School of Mechanical, Medical and Process Engineering, Queensland University of Technology (QUT), Brisbane, QLD4001, Australia; Faculty of Sports Science, Ningbo University, Ningbo, 315211, China.
Article Info
Journal
Computers in biology and medicine
Abbr.
Comput Biol Med
ISSN
1879-0534
Published
2023-00-00
电子出版
2023-00-29
页码
107306
Language
English
Country/Region
United States
NLM ID
1250250
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]