Home LiteratureArticle Details
PMID: 3767356 Published · ppublish English Journal Article Research Support, U.S. Gov't, Non-P.H.S.

Bacteria associated with granular activated carbon particles in drinking water.

Applied and environmental microbiology ·Vol. 52 ·No. 3 ·1986-09-00 ·Pages 434-8

Camper AK, LeChevallier MW, Broadaway SC, McFeters GA

Abstract

A sampling protocol was developed to examine particles released from granular activated carbon filter beds. A gauze filter/Swinnex procedure was used to collect carbon fines from 201 granular activated carbon-treated drinking water samples over 12 months. Application of a homogenization procedure (developed previously) indicated that 41.4% of the water samples had heterotrophic plate count bacteria attached to carbon particles. With the enumeration procedures described, heterotrophic plate count bacteria were recovered at an average rate of 8.6 times higher than by conventional analyses. Over 17% of the samples contained carbon particles colonized with coliform bacteria as enumerated with modified most-probable-number and membrane filter techniques. In some instances coliform recoveries were 122 to 1,194 times higher than by standard procedures. Nearly 28% of the coliforms attached to these particles in drinking water exhibited the fecal biotype. Scanning electron micrographs of carbon fines from treated drinking water showed microcolonies of bacteria on particle surfaces. These data indicate that bacteria attached to carbon fines may be an important mechanism by which microorganisms penetrate treatment barriers and enter potable water supplies.

MeSH Terms
Bacteria/metabolism,ultrastructure Bacterial Adhesion Carbon Filtration Microscopy, Electron, Scanning Water Microbiology Water Supply
Chemicals
Carbon
Authors & Affiliations
4 authors, click to expand affiliations / ORCID
Camper A K
LeChevallier M W
Broadaway S C
McFeters G A
References (7)
7 references, click to expand
  1. Use of nuclepore filters for counting bacteria by fluorescence microscopy.
    Appl Environ Microbiol. 1977 May;33(5):1225-8 PMID: 327932
  2. Enumeration and characterization of standard plate count bacteria in chlorinated and raw water supplies.
    Appl Environ Microbiol. 1980 Nov;40(5):922-30 PMID: 7447444
  3. Effect of turbidity on chlorination efficiency and bacterial persistence in drinking water.
    Appl Environ Microbiol. 1981 Jul;42(1):159-67 PMID: 7259162
  4. Growth and persistence of pathogens on granular activated carbon filters.
    Appl Environ Microbiol. 1985 Dec;50(6):1378-82 PMID: 3911903
  5. Disinfection of bacteria attached to granular activated carbon.
    Appl Environ Microbiol. 1984 Nov;48(5):918-23 PMID: 6508306
  6. A new medium for the enumeration and subculture of bacteria from potable water.
    Appl Environ Microbiol. 1985 Jan;49(1):1-7 PMID: 3883894
  7. New medium for improved recovery of coliform bacteria from drinking water.
    Appl Environ Microbiol. 1983 Feb;45(2):484-92 PMID: 6338827
Article Info
Journal
Applied and environmental microbiology
Abbr.
Appl Environ Microbiol
ISSN
0099-2240
Published
1986-09-00
Pages
434-8
Language
English
Region
United States
NLM ID
7605801
PMCID
PMC203552
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]