Home LiteratureArticle Details
PMID: 37735305 Published · epublish English

The influence of contralateral circulation on computational fluid dynamics of intracranial arteries: simulated versus measured flow velocities.

European radiology experimental ·Vol. 7 ·No. 1 ·2023-00-22

Oh S, Song Y, Lim H, Ko Y, Park S

Abstract

This study aimed to retrospectively evaluate the influence of contralateral anterior circulation on computational fluid dynamics (CFD) of intracranial arteries, by comparing the CFD values of flow velocities in unilateral anterior circulation with the measured values from phase-contrast magnetic resonance angiography (PC-MRA). We analyzed 21 unilateral anterior circulation models without proximal stenosis from 15 patients who performed both time-of-flight MRA (TOF-MRA) and PC-MRA. CFD was performed with the inflow boundary condition of a pulsatile flow of the internal carotid artery (ICA) obtained from PC-MRA. The outflow boundary condition was given as atmospheric pressure. Simulated flow velocities of the middle cerebral artery (MCA) and anterior cerebral artery (ACA) from CFD were compared with the measured values from PC-MRA. The velocities of MCA were shown to be more accurately simulated on CFD than those of ACA (Spearman correlation coefficient 0.773 and 0.282, respectively). In four models with severe stenosis or occlusion of the contralateral ICA, the CFD values of ACA velocities were significantly lower (< 50%) than those measured with PC-MRA. ACA velocities were relatively accurately simulated in the models including similar diameters of both ACAs. It may be necessary to consider the flow condition of the contralateral anterior circulation in CFD of intracranial arteries, especially in the ACA. Incorporating the flow conditions of the contralateral circulation is of clinical importance for an accurate prediction of a rupture risk in Acom aneurysms as the bidirectional flow and accurate velocity of both ACAs can significantly impact the CFD results. • CFD simulations using unilateral vascular models were relatively accurate for MCA. • Contralateral ICA steno-occlusion resulted in an underestimation of CFD velocity in ACA. • Contralateral flow may need to be considered in CFD simulations of ACA.

Keywords
Carotid artery (internal) Hemodynamics Intracranial aneurysm Magnetic resonance angiography Pulsatile flow
MeSH 主题词
Humans Constriction, Pathologic Hydrodynamics Retrospective Studies Arteries Pulsatile Flow
Article Info
Journal
European radiology experimental
Abbr.
Eur Radiol Exp
ISSN
2509-9280
Corresponding email
Published
2023-00-22
Language
English
Country/Region
England
NLM ID
101721752
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]