Home LiteratureArticle Details
PMID: 38195665 Published · epublish English

Performance of textured dual mobility total hip prosthesis with a concave dimple during Muslim prayer movements.

Scientific reports ·Vol. 14 ·No. 1 ·2024-00-09

Muchammad M, Tauviqirrahman M, Ammarullah MI, Iqbal M, Setiyana B, Jamari J

Abstract

The single mobility bearing as a previous bearing design of total hip prosthesis has severe mobility constraints that can result in dislocation during Muslim (people who follow the Islam as religion) prayer movements, specifically shalat that requires intense movement. There are five intense movements (i.e., bowing, prostration, sitting, transition from standing to prostration, and final sitting) during Muslim prayer that may generate an impingement problem for patients with total hip prosthesis. In this work, textured dual mobility total hip prosthesis with two textured cases (i.e., textured femoral head and textured inner liner) are presented and their performances are numerically evaluated against untextured surface model during Muslim prayer movement. The concave dimple design is chosen for surface texturing, while for simulating femoral head materials, SS 316L and CoCrMo is choosen. To represent the real condition, three-dimensional computational fluid dynamics (CFD) coupled with two-way fluid-structure interaction (FSI) methods are employed to analyze elastohydrodynamic lubrication problem with non-Newtonian synovial fluid model. The main aim of the present study is to investigate the tribological performance on dual mobility total hip prosthesis with applied textured surface with concave dimple in femoral head and inner liner surface under Muslim prayer movements. It is found that applying surface texturing has a beneficial effect on the lubrication performance for some intense movements. The textured femoral head model performs better than textured inner liner model and untextured model (both femoral head and inner liner). The numerical results also indicate superior performance of CoCrMo femoral head compared to SS 316L femoral head. These findings can be used as a reference for biomedical engineers and orthopedic surgeons in designing and choosing suitable total hip prosthesis for Muslims makes they can carry out Muslim prayer movements like humans in general who have normal hip joints.

MeSH 主题词
Humans Islam Hip Prosthesis Arthroplasty, Replacement, Hip Hip Joint Biomedical Engineering
Article Info
Journal
Scientific reports
Abbr.
Sci Rep
ISSN
2045-2322
Corresponding email
Published
2024-00-09
Language
English
Country/Region
England
NLM ID
101563288
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]