Home LiteratureArticle Details
PMID: 38244472 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't

Mechanism of effect of stenting on hemodynamics at iliac vein bifurcation.

Computers in biology and medicine ·Vol. 170 ·2024-00-00 ·页码 107968

Hu J, Feng H, Zheng Y, Wang K, Wang X, Su J

Abstract

When performing stent intervention for iliac vein compression syndrome, the operator selects the appropriate stent and determines its implantation depth according to the type and severity of iliac vein stenosis in the patient. However, there is still uncertainty regarding how the structure of the stent and its implantation depth affect hemodynamics at the site of lesion. In this paper, we analyzed three commonly used stents (Vena stent from Venmedtch, Venovo from Bard, and Smart stent from Cordis) with different implantation depths (0, 10, 20 mm) using computational fluid dynamics (CFD). We focused on evaluating hemorheological parameters such as time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), etc., within one pulsatile cycle after stent implantation. The correlation between geometric parameters of the stents and hemodynamic indicators was assessed using Pearson correlation coefficient (r), which was further validated through PIV velocity measurement experiment. The results revealed that an increase in implantation depth led to a more pronounced disturbance effect on blood flow at bifurcation for densely arranged support body-type stents. This effect was particularly significant during periods of smooth blood flow. On the other hand, crown-shaped Vena stents exhibited relatively less disruption to blood flow post-implantation. Implantation depth showed a strong negative correlation with TAWSS but a strong positive correlation with OSI and RRT. These findings suggest an increased risk of thrombosis at iliac vein bifurcation following stent placement. Amongst all three tested stents, Vena Stent demonstrated more favorable periodic parameters after implantation compared to others. These results provide valuable theoretical insights into understanding contralateral circulation thrombosis associated with iliac vein stenting.

Keywords
Finite element method Hemodynamics Iliac vein stent PIV Wall shear stress
MeSH 主题词
Humans Iliac Vein/surgery Hemodynamics Stents/adverse effects Thrombosis
作者与单位
共 6 位作者,点击展开单位 / ORCID
Hu Jinming
College of Mechanical Engineering, Inner Mongolia University of Technology, Hohhot, 010000, PR China.
Feng Haiquan
College of Mechanical Engineering, Inner Mongolia University of Technology, Hohhot, 010000, PR China. Electronic address: [email protected].
Zheng Yilin
College of Mechanical Engineering, Inner Mongolia University of Technology, Hohhot, 010000, PR China.
Wang Kun
College of Mechanical Engineering, Inner Mongolia University of Technology, Hohhot, 010000, PR China.
Wang Xiaotian
The First Affiliated Hospital of University of Science and Technology of China, Hefei, PR China.
Su Juan
School of Materials Science and Engineering, Inner Mongolia University of Technology, Hohhot, 010051, PR China. Electronic address: [email protected].
Article Info
Journal
Computers in biology and medicine
Abbr.
Comput Biol Med
ISSN
1879-0534
Published
2024-00-00
电子出版
2024-00-06
页码
107968
Language
English
Country/Region
United States
NLM ID
1250250
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]