Flow characterization of Maquet and Bio-Medicus multi-stage drainage cannulae during venoarterial extracorporeal membrane oxygenation.

Computers in biology and medicine ·Vol. 171 ·2024-00-00 ·页码 108135

Wickramarachchi A, Gregory SD, Burrell AJC, Khamooshi M

Abstract

Drainage cannulae extract blood from a patient during venoarterial extracorporeal membrane oxygenation (VA ECMO), a treatment that temporarily supports patients undergoing severe heart and/or lung dysfunction. Currently, the two most commonly used multi-stage drainage cannulae are manufactured by Maquet and Bio-Medicus, but their designs vary in many aspects which impacts the generated flow dynamics. Therefore, this study aimed to use computational fluid dynamics (CFD) to explore the flow characteristics of the aforementioned cannulae and their impact on complications such as thrombosis. The Maquet and Bio-Medicus cannulae were 3D modelled within a patient-specific geometry of the venous vasculature taken from a computed tomography scan of a patient undergoing VA ECMO. A drainage flow rate of 4 L/min was assigned to each cannula. Lastly, a stress blended eddy simulation turbulence model was employed to resolve bulk flow turbulence. The proximal row of side holes in both cannulae generated high intensity counter-rotating vortices, thus generating supraphysiological shear. These proximal rows were also responsible for the majority of flow extraction in both cannulae (>1.6 L/min). Despite identical simulation settings, each cannulae had differing impacts on global flow dynamics. For instance, the Bio-Medicus model produced a total stagnant blood volume of 25.6 ml, compared to 17.8 ml the Maquet cannula, thereby increasing the risk of thrombosis. Overall, our results demonstrate that differences in design clearly impact flow dynamics and risk of complications. Therefore, further work in optimizing cannula design may be beneficial to prevent harmful flow characteristics.

Keywords
CFD Computational fluid dynamics Differential oxygenation Thrombosis VA ECMO Venous cannula Vessel collapse
MeSH 主题词
Humans Cannula Extracorporeal Membrane Oxygenation/methods Hemodynamics/physiology Heart Thrombosis/diagnostic imaging
作者与单位
共 4 位作者,点击展开单位 / ORCID
Wickramarachchi Avishka
Cardio-Respiratory Engineering and Technology Laboratory, Department of Mechanical and Aerospace Engineering, Monash University, 631 Blackburn Road, Clayton, VIC, Australia. Electronic address: [email protected].
Gregory Shaun D
Cardio-Respiratory Engineering and Technology Laboratory, Department of Mechanical and Aerospace Engineering, Monash University, 631 Blackburn Road, Clayton, VIC, Australia.
Burrell Aidan J C
Department of Intensive Care, Alfred Hospital, 55 Commercial Road, Melbourne, VIC, Australia; Australian and New Zealand Intensive Care Research Centre, Monash University, Melbourne, VIC, Australia.
Khamooshi Mehrdad
Cardio-Respiratory Engineering and Technology Laboratory, Department of Mechanical and Aerospace Engineering, Monash University, 631 Blackburn Road, Clayton, VIC, Australia.
Article Info
Journal
Computers in biology and medicine
Abbr.
Comput Biol Med
ISSN
1879-0534
Corresponding email
Published
2024-00-00
电子出版
2024-00-16
页码
108135
Language
English
Country/Region
United States
NLM ID
1250250
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]