Home LiteratureArticle Details
PMID: 38373739 Published · ppublish English

Cochlear-facial dehiscence - the most common cause of facial nerve stimulation from a cochlear implant? A case-control study.

Cochlear implants international ·Vol. 25 ·No. 2 ·2024-03-00

Bunne M, Myhrum M, Iftikhar M, Rasmussen K, Falkenberg-Jensen B

Abstract

Objectives: To investigate the prevalence of cochlear-facial dehiscence (CFD) and other radiographical pathologies in ears with facial nerve stimulation (FNS) from a cochlear implant (CI). Methods: Retrospective case-control study of 27 patients with CI and FNS on either ear (study group) and 27 patients without FNS, matched for age, sex and type of electrode array (control group). Preoperative CT scans of all 108 ears were re-evaluated. Subanalyses included comparisons between the study and control groups and associations between FNS and radiographic pathologies. Results: CFDs were detected in 20 of 54 ears (37%) in the study group and in 3 of 54 ears (6%) in the control group (P < 0.001). The corresponding numbers of otosclerosis were 10 (18%) and 0 (P = 0.011) and of developmental anomalies 16 (30%) and 8 (15%) (not significant). FNS was present in 33 ears in the study group, of which 14 (42%) had a CFD. FNS was absent in six ears with CFD and CI, four of which contralateral to an ear with FNS. Eight of 14 ears with FNS and CFD had a lateral electrode array and six had a perimodiolar electrode array. We found no association between the presence of CFD and stimulation thresholds for FNS. The adjusted odds ratio for developing FNS in the presence of a CFD was 9.9 (95% CI 2.7-36.0). Conclusions: CFD was the most common radiographic pathology in ears with FNS, with a 10-fold increased risk of FNS. To avoid CI-related FNS, preoperative CT scan and awareness of typical dehiscence symptoms are strongly recommended.

Keywords
Cochlear implant cochlear-facial dehiscence facial nerve stimulation fracture temporal bone otic capsule dehiscence otosclerosis‌ radiographic inner ear pathology third window syndrome
MeSH 主题词
Humans Female Male Case-Control Studies Retrospective Studies Cochlear Implants/adverse effects Cochlear Implantation/adverse effects Middle Aged Adult Facial Nerve Tomography, X-Ray Computed Child Aged Adolescent Child, Preschool Young Adult Cochlea/diagnostic imaging,abnormalities Otosclerosis/surgery
Article Info
Journal
Cochlear implants international
Abbr.
Cochlear Implants Int
ISSN
1754-7628
Published
2024-03-00
Language
English
Country/Region
England
NLM ID
101121166
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]