Bronchoscopy is one of the most accurate procedures to diagnose airway stenosis which is an invasive procedure. However, a quick and noninvasive estimation of the percent area of obstruction (%AO) of the lumen is helpful in decision-making before performing a bronchoscopy procedure. We hypothesized that there is a relationship between %AO and tracheal resistance against fluid flow. By measuring airway resistance, %AO could be estimated before the procedure. Using computational fluid dynamics (CFD), this study simulates the fluid flow through trachea models with web-liked stenosis using CFD. A cylindrical segment was inserted into the trachea to represent cross-sectional areas corresponding to 20%, 40%, 60%, and 80% AO. The fluid flow and pressure distribution in these models were studied. Our CFD simulations revealed that the tracheal resistance is exponentially increased by %AO. The results showed a 130% and 55% increase in lung airway resistance and resistive work of breathing for an 80% AO, respectively. Moreover, a curve-fitted relationship was obtained to estimate %AO based on the measured airway resistance by body plethysmography or forced oscillation technique. This pre-estimation is very useful in diagnostic evaluation and treatment planning in patients with tracheal stenosis.
No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong
Qilu Normal University · Genelibs Bioinformatics Lab
750 Shunhua Rd, Jinan
2F, Bldg F, University Science Park
Tel: 0531-88819269
Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.
Business Email
E-mail: [email protected]