Home LiteratureArticle Details
PMID: 38765874 Published · ppublish English

Validation of ultrasound velocimetry and computational fluid dynamics for flow assessment in femoral artery stenotic disease.

Journal of medical imaging (Bellingham, Wash.) ·Vol. 11 ·No. 3 ·2024-05-00

van de Velde L, van Helvert M, Engelhard S, Ghanbarzadeh-Dagheyan A, Mirgolbabaee H, Voorneveld J, Lajoinie G, Versluis M, Reijnen MMPJ, Groot Jebbink E

Abstract

To investigate the accuracy of high-framerate echo particle image velocimetry (ePIV) and computational fluid dynamics (CFD) for determining velocity vectors in femoral bifurcation models through comparison with optical particle image velocimetry (oPIV). Separate femoral bifurcation models were built for oPIV and ePIV measurements of a non-stenosed (control) and a 75%-area stenosed common femoral artery. A flow loop was used to create triphasic pulsatile flow. In-plane velocity vectors were measured with oPIV and ePIV. Flow was simulated with CFD using boundary conditions from ePIV and additional duplex-ultrasound (DUS) measurements. Mean differences and 95%-limits of agreement (1.96*SD) of the velocity magnitudes in space and time were compared, and the similarity of vector complexity (VC) and time-averaged wall shear stress (TAWSS) was assessed. Similar flow features were observed between modalities with velocities up to 110 and 330  cm/s in the control and the stenosed model, respectively. Relative to oPIV, ePIV and CFD-ePIV showed negligible mean differences in velocity (<3  cm/s), with limits of agreement of ±25  cm/s (control) and ±34  cm/s (stenosed). CFD-DUS overestimated velocities with limits of agreements of 13±40 and 16.1±55  cm/s for the control and stenosed model, respectively. VC showed good agreement, whereas TAWSS showed similar trends but with higher values for ePIV, CFD-DUS, and CFD-ePIV compared to oPIV. EPIV and CFD-ePIV can accurately measure complex flow features in the femoral bifurcation and around a stenosis. CFD-DUS showed larger deviations in velocities making it a less robust technique for hemodynamical assessment. The applied ePIV and CFD techniques enable two- and three-dimensional assessment of local hemodynamics with high spatiotemporal resolution and thereby overcome key limitations of current clinical modalities making them an attractive and cost-effective alternative for hemodynamical assessment in clinical practice.

Keywords
blood flow imaging computational fluid dynamics echo-particle image velocimetry peripheral arterial disease stenotic blood flow ultrafast ultrasound imaging
Article Info
Journal
Journal of medical imaging (Bellingham, Wash.)
Abbr.
J Med Imaging (Bellingham)
ISSN
2329-4302
Published
2024-05-00
Language
English
Country/Region
United States
NLM ID
101643461
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]