Home LiteratureArticle Details
PMID: 39251336 Published · epublish English Journal Article

The aqueous humour dynamics in primary angle closure disease: a computational study.

The British journal of ophthalmology ·Vol. 109 ·No. 3 ·2025-02-24 ·页码 333-339

Fu L, Liu X, Zhang L, Lou J, Zheng X, Wang X, Lin H, Guo L, Wang K, Wang Y, Kan M, Liang Y

Abstract

To create a computational fluid dynamics (CFD) model of ocular anterior segment for primary angle closure diseases (PACD) and assess the aqueous humour (AH) dynamics in different angle closure ranges (ACRs). The ocular anterior segment geometry was obtained from an optical coherence tomography image by SOLIDWORKS. Three different angle opening distance at 750 µm from the scleral spur (AOD750) values were established to mimic three widths of anterior chamber angle. The AH dynamics were modelled using the Navier-Stokes equation. The 3D CFD model of the ocular anterior segment was created in COMSOL Multiphysics. The major outcome was the maximum flow velocity (MFV) and pressure in the ocular anterior segment. An in vitro simulation model was used to validate the computational results of the pressure and ACRs. The MFV and pressure both showed a non-linear association with ACR in the CFD models of PACD. The MFV and pressure started to elevate when ACR was larger than 180°, and increased dramatically when the ACR was larger than 270°. The in vitro experiment of the pressure changes was consistent with the CFD model. No significant differences of the MFV and pressure among the three AOD750 models. The association among the ACR, MFV and pressure is an ascending curve in PACD, and ACR of 180° and 270° are two critical turning points. Our results are consistent with clinical phenomenon and may be used to provide better guidances for the clinical management of PACD in different stages.

Keywords
Aqueous humour Glaucoma
MeSH 主题词
Aqueous Humor/physiology Humans Tomography, Optical Coherence Glaucoma, Angle-Closure/physiopathology Hydrodynamics Intraocular Pressure/physiology Computer Simulation Anterior Eye Segment/physiopathology,diagnostic imaging
作者与单位
共 12 位作者,点击展开单位 / ORCID
Fu Lin ORCID
National Clinical Research Center for Ocular Diseases, EyeHospital, Wenzhou Medical University Eye Hospital, Wenzhou, 325027, China. | National Engineering Research Center of Ophthalmologyand Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China. | State Key Laboratory of Ophthalmology, Optometry andVisual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
Liu Xinyi ORCID
Department of Ophthalmology, People's Hospital of Yichun, Yichun, Jiangxi, China.
Zhang Longqian
Faculty of Engineering and Applied Science, Ontario Tech University, Oshawa, Ontario, Canada.
Lou Jiangtao
National Clinical Research Center for Ocular Diseases, EyeHospital, Wenzhou Medical University Eye Hospital, Wenzhou, 325027, China. | National Engineering Research Center of Ophthalmologyand Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China. | State Key Laboratory of Ophthalmology, Optometry andVisual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
Zheng Xiaobo
National Clinical Research Center for Ocular Diseases, EyeHospital, Wenzhou Medical University Eye Hospital, Wenzhou, 325027, China. | National Engineering Research Center of Ophthalmologyand Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China. | State Key Laboratory of Ophthalmology, Optometry andVisual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
Wang Xiaojue
National Clinical Research Center for Ocular Diseases, EyeHospital, Wenzhou Medical University Eye Hospital, Wenzhou, 325027, China.
Lin Haishuang ORCID
National Clinical Research Center for Ocular Diseases, EyeHospital, Wenzhou Medical University Eye Hospital, Wenzhou, 325027, China.
Guo Liang
Suzhou Purevision Medical Technology Co., LTD, Suzhou, China.
Wang Kezhao
Suzhou Purevision Medical Technology Co., LTD, Suzhou, China.
Wang Yan
Suzhou Purevision Medical Technology Co., LTD, Suzhou, China.
Kan Min
Suzhou Purevision Medical Technology Co., LTD, Suzhou, China.
Liang Yuanbo ORCID
National Clinical Research Center for Ocular Diseases, EyeHospital, Wenzhou Medical University Eye Hospital, Wenzhou, 325027, China [email protected]. | National Engineering Research Center of Ophthalmologyand Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China. | State Key Laboratory of Ophthalmology, Optometry andVisual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
Article Info
Journal
The British journal of ophthalmology
Abbr.
Br J Ophthalmol
ISSN
1468-2079
Corresponding email
Published
2025-02-24
电子出版
2025-00-24
页码
333-339
Language
English
Country/Region
England
NLM ID
0421041
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]